EN
AC Connector: An appropriate AC line cord and plug are provided. 220 VAC, 50Hz/60Hz units
have a standard 3-wire, 15-amp grounded connector
Controls
Power: A front panel switch is used to turn the amplifier on and off.
Level: A front panel rotary potentiometer for each channel is used to control the output level.
Stereo/Mono:A three-position back panel switch is used to select Stereo, Bridge-Mono or
Parallel-Mono mode.
Input/Output Data
Input Connector: Balanced XLR connector and RCA unbalanced.
Input Impedance: Nominally 20k ohms, balanced; 10 k ohms, unbalanced.
Output Connector: Two sets of color-coded 5-way binding posts (for banana plugs, spade lugs or
bare wire) .
Output Signal Modes
Stereo: Balanced, two-channel.
Bridge-Mono: Balanced, single-channel. Channel 1 inputs are active; Both channel volume
controls are available.
Parallel-Mono: Balanced, single-channel. Channel 1 inputs are active; Both channel volume
controls are available.
Frequencie response 20-20KHz
Dimension/WxDxH/mm
MODEL
THD
Power Handling
8 ohm per Channel
4 ohm per Channel
8 ohm bridged
S/N Ratio
Slew rate
Damping factor
Mode switch
Stereo/Parallel/ Bridge
Crosstalk
Power ON delay
Input Sensitivity
Input connection
Link connection
Output connection
Soft start
Operating Voltage
Net weight
WCE200
0.05%
150W
220W
500W
>65dB
5V/us
300
Stereo/Parallel/ Bridge
>46dB
7 sec
0.7V
< +/- 0.25dB
XLR
RCA
Binding post
yes
185-245V
483x277x44
3.7kg
User Manual/Manual de Uso
7
WCE400
0.05%
220W
380W
800W
>67dB
5V/us
300
>46dB
7 sec
0.8V
< +/- 0.25dB
XLR
RCA
Binding post
yes
185-245V
483x277x89
4.5kg
WCE 200/400