10.5 Short-press the
GB
Caution:
Only a K-type thermocouple can be used.
Max. temperature 230°C/446°F (°F = °C × 1.8 + 32)
11. AC/DC current measurement (P 13)
DM 620
USB
11.1 Insert the red test lead into the mA/μA or A terminal, and the black test lead into the COM
terminal.
11.2 Turn the function dial to the
11.3 Short-press the
11.4 Connect the test leads in series with the measured load or power supply.
11.5 Read the current value on the display (if the current is >10 A, the red indicator light will be on and
the buzzer will sound an alarm).
11.6 When measuring AC current, short-press the
the measured current.
Caution:
To prevent possible electric shock, fire, or personal injury, switch off the power supply to the circuit,
then connect the meter in series with the circuit before measuring the current.
If the range of the measured current is unknown, select the maximum range and then reduce
accordingly.
There are fuses inside mA/μA and A input terminals. Do not connect the test leads in parallel with
any circuit.
If the measured current is >5 A, each measurement time should be ≤10 s and the rest interval should
be ≥15 minutes.
If the temperature of the meter rises above 75°C after measurement of a large current, the yellow
indicator light will come on, the buzzer will beep, and the LCD will display "CUT". When the
temperature drops to <40°C, the yellow indicator light will turn off, and the measurement can be made.
14
button to switch between °C and °F.
A C/DC
RL
RL
P 13
,
button to switch to AC/DC current measurement if required.
or
position.
button to display the frequency/duty ratio of
USB