Expansion modules
No.
15/16
17/18
19/20
21/22
23/24
25/26
27/28
29/30
31/32
33/34
35/36
37/38
39/40
41/42
43/44
45/46
47/48
49/50
Bosch Sicherheitssysteme GmbH
Connections
Features
+12 V / 0 V control
+12 V / 0 V switched minus potential, maximum output
output S3
current 20 mA, e.g. activation of relay module
+12 V / 0 V control
+12 V / 0 V switched minus potential, maximum output
output S4
current 100 mA
–
–
+12 V / 0 V Output Power output for external devices, output current maximum
100 mA
SP
Spare, connected internally
SP
Spare, connected internally
SP
Spare, connected internally
SP
Spare, connected internally
SP
Spare, connected internally
PL 1
Primary line for connection of detector zone 1
SP
Not connected, designed for external resistor (EOL):
–
–
PL 2
Primary line for connection of detector zone 2
SP
Not connected, designed for external resistor (EOL):
–
–
PL 3
–
–
–
SP
Not connected, designed for external resistor (EOL):
–
–
PL 4
–
–
SP
Not connected, designed for external resistor (EOL):
–
–
Earth inputs for cable shield (if available), 47 and 48
connected internally
PL 5
–
–
–
Installation Manual
E.g. activation of relay module
Blocklock magnet "BSM" at NBS 10, (wire color: 17 =
yellow, 18 = blue / red)
12k1 for ISP-EMIL-120 and ISP-PCBA-EMIL
4k7 for ISP-EMIL-3RDP
12k1 for ISP-EMIL-120 and ISP-PCBA-EMIL
4k7 for ISP-EMIL-3RDP
Primary line for connection of detector zone 3
Blocklock primary line at NBS 10, (wire color: 39 =
black, 40 = blue)
Coded arming device
12k1 for ISP-EMIL-120 and ISP-PCBA-EMIL
4k7 for ISP-EMIL-3RDP
Primary line for connection of detector zone 4
Coded arming device
12k1 for ISP-EMIL-120 and ISP-PCBA-EMIL
4k7 for ISP-EMIL-3RDP
Primary line for connection of detector zone 5 or
Connection of line-fed glass break detectors
Block-type lock tamper detector zone at NBS 10, (wire
color: 49 = white, 50 = brown)
Pin assignment | en
25
2017.09 | 04 | F.01U.076.548