3. Operation
<Returning to the Operation menu>
Operation
Vane·Louver·Vent. (Lossnay)
High power
Comfort
Main menu: RETURN
Cursor
ON
RETURN SELECT
MENU
OFF
HOLD
Note:
During swing operation, the directional indication on the screen
●
does not change in sync with the directional vanes on the unit.
Available directions depend on the type of unit connected.
●
In the following cases, the actual air direction will differ from the
●
direction indicated on the remote controller display.
1. While the display is in "STAND BY" or "DEFROST" states.
2. Immediately after starting heat mode (while the system is wait-
ing for the mode change to take effect).
3. In heat mode, when room temperature is higher than the tem-
perature setting.
4. Timer
■
Timer functions are different by each remote controller.
■
For details on how to operate the remote controller, refer to the appropriate operation manual included with each remote controller.
5. Emergency Operation for Wireless Remote-controller
Press the [RETURN] button to go
back to the Operation menu.
C
D
B
A
E
<[Manual] To Change the Airflow's Left/Right Direction>
* The louver button cannot be used.
• Stop the unit operation, hold the lever of the
louver, and adjust to the desired direction.
* Do not set to the inside direction when the
unit is in the cooling or drying mode because
there is a risk of condensation and water
dripping.
Caution:
To prevent falls, maintain a stable footing when operating the unit.
3.6. Ventilation
For LOSSNAY combination
■
The following 2 patterns of operation is available.
• Run the ventilator together with indoor unit.
• Run the ventilator independently.
Note: (for wireless remote controller)
Running the ventilator independently is not available.
●
No indication on the remote controller.
●
When the remote controller cannot be used
When the batteries of the remote controller run out or the remote
controller malfunctions, the emergency operation can be done using the
emergency buttons on the grille.
A STANDBY lamp
B OPERATING lamp
C Emergency operation cooling switch
D Emergency operation heating switch
E Receiver
Starting operation
• To operate the cooling mode, press the
• To operate the heating mode, press the
• Lighting of the OPERATING lamp B means the start of operation.
Note:
Details of emergency mode are as shown below.
Details of EMERGENCY MODE are as shown below.
Operation mode
Set temperature
24°C, 75°F
Fan speed
Airflow direction
Horizontal (Step 1)
Stopping operation
• To stop operation, press the
than 2 seconds.
button C for more than 2 seconds.
button D for more than 2 seconds.
COOL
HEAT
24°C, 75°F
High
High
Downward (Step 5)
button C or the
button D for more
en
10