Dead air area
0.9m
Single Story
one sleeping area
LIVING ROOM
BEDROOM
STUDY
BEDROOM
BEDROOM
R
OOM
Single Story
more than one sleeping areas
DINING
KITCHEN
BEDR
OOM
ROOM
BEDR
TV ROOM
LIVING ROOM
PAGE:07
KITCHEN
DINING
ROOM
OOM
BEDROOM
Two Story dwelling
BEDROOM
HALL
BEDROOM
LIVING
KITCHEN
ROOM
FINIBHED
BASEMENT
GARAGE
IMPORTANT:
These alarms are intended to primarily for single-occupancy private dwellings. For use in
other applications the manufacturer's advice must be sought.
4.LOCATIONS TO AVOID
DO NOT locate smoke alarms:
4.1
In turbulent air from fans, heaters, doors, windows, etc., which could draw smoke away
from the alarm.
4.2
In high humidity area such as bathrooms and shower rooms, or where the temperature
exceeds 39
or falls below
℃(100℉)
alarm.
4.3 At the peal of an "A" frame ceiling. "Dead air" at the top may prevent smoke from
reaching the alarm in time to provide early warning.
4.4 Less than 300mm (12 inches) from the wall when mounted on the ceiling.
Additional smoke
alarms for better
coverage
Smoke alarms for
limited protection
Heat alarms
, as high humidity can trigger nuisance
5℃(40℉)
EN
PAGE:08