Descargar Imprimir esta página

Hoover TurboPOWER Auto Rinse Manual De Instrucciones página 16

Publicidad

Idiomas disponibles

Idiomas disponibles

Storage
Before storing:
• Empty clean water tank and let air
dry. Replace on carpet cleaner.
• Unused detergent can be stored in
the detergent container.
• Empty recovery tank, rinse tank
and lid thoroughly with clean water
and let air dry.
Allow brushes and underside of car-
pet cleaner to air dry thoroughly
before storing carpet cleaner on a car-
peted or wood surface.
Do not store carpet cleaner with a full
clean water tank in place.
Possible cause
5. If you have a
Possible solution
problem
• Recovery tank full/automatic
If a minor problem occurs, it usually can
be solved quite easily when the cause is
found by using the check list below.
Problem: Machine won't run
Possible cause
Possible solution
• Not firmly plugged in
• Plug unit in firmly
• No voltage in wall receptacle
• Check fuse or breaker
• Blown fuse/tripped breaker
• Replace fuse/reset breaker
Problem: Low solution pick-up
Possible cause
Possible solution
• Recovery tank full/automatic shut
off engaged
• Remove and empty recovery tank
• Blockage in tool on end of hose
• Remove tool and clear blockage
• Recovery tank lid not on correctly
• Make sure lid is on securely
• Water tank empty, but detergent
remains
• Fill water tank
16
All manuals and user guides at all-guides.com
Lubrication
The motor is equipped with bearings
which contain sufficient lubrication for
the life of the motor. The addition of
lubricant could cause damage. Do not
add lubricant to motor bearings.
Problem: Clean water won't
dispense
Possible cause
Possible solution
• Clean water tank not firmly in place
• Make sure tank is securely locked in
position
• Clean water tank or detergent
container empty
• Refill container according to instruc-
tions for surface being cleaned
• Recovery tank lid not on
correctly
• Make sure lid is firmly in place
Problem: Detergent won't
dispense
Possible cause
Possible solution
• Valve cap clogged
• Remove and clean valve cap (see fol-
lowing instructions)
1. Remove clean water tank.
5-1
A
2. Turn valve cap (A) counterclockwise
and remove.
Soak valve cap in warm water for at
least 15 minutes. Wipe cap dry.
5-2
B
3. Align slots (B) on cap with tabs (C) in
opening.
Turn cap clockwise to tighten.
Problem: Brushes won't rotate during
floor cleaning
Possible cause
Possible solution
• Dirty filter screen on bottom of unit
• Clean screen as shown in Fig. 3-2
• SpinScrub mode selector on SPILL
PICK-UP.
• Slide mode selector to GENTLE
SCRUB or POWER SCRUB.
A