Replacing the lamp

Before replacing the lamp, unplug mains lead and let the lamp cool down (approx. 5 minutes).
During the installation do not touch the glass-bulbs bare-handed! Please follow the lamp manufacturer's
notes!
Do not install lamps with a higher wattage! Lamps with a higher wattage generate temperatures the device
was not designed for. Damages caused by non-observance are not subject to warranty.
For the installation, you need one XOP-15 flash tube.
During the operation, the lamp reaches temperatures of up to 550° C.
Procedure:
Step 1: Unscrew the fixation screws of the protective shield.
Step 2: Remove the protective shield.
Step 3: Remove the old lamp from the lamp-socket.
Step 4: Insert the new XOP-15 flash tube lamp into the lamp-socket.
Step 5: Replace the protective shield and tighten the screws.
TECHNICAL SPECIFICATIONS
Power supply:
Power consumption:
Dimensions (LxWxH):
Weight:
Fitting lamp:
Maximum ambient temperature t
Maximum housing temperature t
Fuse:
Please note: Every information is subject to change without prior notice. 9/00 ©
DANGER TO LIFE!
Only install the lamp with the device switched off!
Unplug from mains before!
CAUTION!
The lamp has to be replaced when it is damaged
or deformed due to the heat!
Do not operate this device with opened protective shield!
230 V AC, 50 Hz ~
3500 W
520 x 135 x 215 mm
6 kg
XOP-15 flash tube
:
45° C
a
(steady state):
130° C
B
16 A circuit breaker