4.2.5 FREEZE PROTECTION MODE.
When knob A is in the Freeze protection position, the
radiator maintains the ambient temperature at 7 °C
(cannot be changed).
4.2.6 CHRONO/PROGRAMMING MODE.
When knob A is in the Chrono position, the ambient
temperature will be equal to the Comfort or Night
temperature, depending on the programming you have
set.
4.2.7 STAND-BY/STOP MODE.
When knob A is in the Stop position, the radiator remains
off. Remember, however, that it is still connected to the
power mains and electrically powered.
4.3 OTHER FUNCTIONS OF THE RADIATOR
4.3.1 ASC - ADAPTIVE CONTROL OF PROGRAMMED STARTS.
If this parameter is enabled and the appliance is in PROGRAMMING mode, the electronics activates the radiator in advance (up to 2
hours) so as to ensure that the room reaches the set temperature at the desired time.
ASC is displayed when this mode is active.
4.3.2 WINDOW OPENING DETECTION FUNCTION
The radiator is able to identify whether a window has been opened through detection of a quick ambient temperature reduction
(5°C at least in a maximum of 30 minutes). If this happens, the radiator switches off for 30 minutes and then it restarts working in
the previously set mode if it detects a subsequent increase in temperature of at least one degree centigrade (the window has been
closed), otherwise it remains off for an additional 30 minutes.
When the function is active, the symbol
is displayed and flashes if window opening is detected.