Fig. 1 Measurement on an external resistor-capacitor
pair
6.4 Measurement of charging time
Set the function switch to CHARGE – STOP.
Set the reference level selector to the re-
quired voltage.
Briefly press the the RESET button to reset
the digital counter to zero.
Set the function switch to CHARGE – START,
to start charging and measurement of time.
Make a note of the time measured as soon as
the counter stops.
6.5 Measurement of discharging time
Follow a similar procedure as for the charg-
ing curve, except that the function switch
should be set to DISCHARGE – STOP and
then DISCHARGE – START.
7. Experiments
7.1 Plotting of charging curve
Set the voltage level selector to 0.5 V and
determine the charging time as specified
under 6.4.
To measure the time for the next value, turn
the selector switch up to the next level and
repeat each step of the procedure.
U / V
10
8
6
4
2
0
0
10
20
Fig. 2 Charging curve for built-in RC pair no. 3
7.2 Plotting of discharging curve
Set the voltage level selector to 9.5 V and
determine the discharging time as specified
under 6.5.
To measure the time for the next value, turn
the selector switch down to the next level
and repeat each step of the procedure.
U / V
10
8
6
4
2
0
0
10
20
Fig. 3 Discharging curve for built-in RC pair no. 3
3
30
40
50
60
t / s
30
40
50
60
t / s
70
70