Descargar Imprimir esta página

KWC F5ST2034 Instrucciones De Montaje Y Servicio página 4

Publicidad

Installation and operating
EN
instructions
Important notes
► Before installing flush piping system!
► Set the scald protection after assembly has
been completed.
► The fitting must be operated only with
original mesh filters and return flow
inhibitors!
► The fitting must be checked and
maintained at regular intervals depending
on the water quality and in accordance with
the local conditions, and rules and
regulations applicable at the site.
Technical data
► Minimum flow pressure 1.0 bar
► Maximum operating pressure 10 bar
► Recommended flow pressure 3 bar
► Volume flow 15 l/min
► Thermostatic scald protection according to
DIN EN 1111
► maximum operating temperature
- continuous operation 70° C
- short-term (<10 min) 90° C
► Flow duration 5-35 s adjustable
DE
Montage- und Betriebsanleitung
Wichtige Hinweise
► Vor Installation Rohrleitungen spülen!
► Nach erfolgter Montage den
Verbrühungsschutz einstellen!
► Armatur nur mit original Sieben und
Rückflussverhinderern betreiben!
► In Abhängigkeit von der Wasserqualität,
den örtlichen Gegebenheiten und den vor
Ort geltenden Bestimmungen die Armatur
in regelmäßigen Abständen prüfen und
warten.
Technische Daten
► Mindestfließdruck 1,0 bar
► Maximaler Betriebsdruck 10 bar
► Empfohlener Fließdruck 3 bar
► Volumenstrom 15 l/min
► Thermostatischer Verbrühungsschutz laut
DIN EN 1111
► maximale Betriebstemperatur
- Dauerbetrieb 70° C
- Kurzzeit (<10 min) 90° C
► Fließzeit 5-35 s einstellbar
- 4 -