GB
Personal safety
Commence work in good physical and psychological conditions. Pay attention to what you do. Do not work if you are
tired or under eff ects of medicines or alcohol. Even a moment's inattention during work may lead to serious injuries.
Always use individual means of protection. Always wear goggles. Using individual means of protection, such as dust-masks,
protective shoes, helmets and hearing protections permits to reduce the risk of serious injuries.
Avoid accidental activation of the tool. Make sure the switch is in the OFF position, before you connect the tool to the
mains. Holding the tool with a fi nger on the switch or connecting an electric tool when the switch is in the ON position may lead
to serious injuries.
Before you turn an electric tool on remove all the spanners and other tools, which have been used for adjustments. A
spanner left on rotating elements of the tool may lead to serious injuries.
Keep your balance. Maintain an appropriate position. It will permit to control the electric tool in case of unpredicted situations
during its operation.
Use protective clothes. Do not wear loose clothes or jewellery. Keep your hair, clothes and gloves away from moving
elements of the electric tool. Loose clothes, jewellery or long hair may get caught on moving elements of the tool.
Use dust extractors or dust containers, if the tool is equipped with any. Make sure they are properly connected. Using of
dust extractors permits to reduce the risk of serious injuries.
Operation of the electric tool
Do not overload the electric tool. Use a proper tool for the given purpose. A correct selection of the tool for the given work
will result in a more effi cient and safer work.
Do not use the electric tool if the switch is not functioning properly. A tool which may not be controlled by means of a switch
is dangerous and must be repaired.
Disconnect the plug from the mains socket before any adjustment, replacement of accessories or storage of the tool. It
will permit to avoid accidental activation of the electric tool.
Store the tool away from children. Do not allow untrained persons to operate the tool. An electric tool may be dangerous
in hands of an untrained person.
Make sure the tool is properly maintained. Check the tool in order to detects any unfi tting or loose moving elements.
Check whether the elements of the tool are not damaged. In case any damaged elements of the tool are detected, they
must be repaired before the electric tool is operated. Many accidents are caused by improper maintenance of tools.
Cutting tools must be sharp and clean. Properly maintained cutting tools are easier to control during work.
Use electric tools and accessories in accordance with the aforementioned instructions. Use the tool in accordance with
its purpose, taking into account the kind and conditions of work. Should the tool be used for other applications than the ones
it has been designed for, the risk of a dangerous situation increases.
Repairs
The tool may be repaired only by authorised service centres, which must use solely original spare parts. It will guarantee
a proper level of safety of operation of the electric tool.
ADDITIONAL SAFETY INSTRUCTIONS
Do not use the product for other purposes than mixing mortars, paints and other liquid construction masses. Do not assemble with
a mixer other accessories than agitator, e.g. nog plates, polishers, drills etc. Do not use mixer for mixing powdery products.
All accessories mounted with mixer must have maximum rotational speed not higher than rated speed of the product. It is forbid-
den to use accessories of maximum permissible rotational speed lower than rated speed of the product.
Do not use defective agitators. If any cracks or bends of the mixer's spindle are found, it should be replaced with an agitator free
from defects. Check the condition of accessories and the product before each start.
Use agitators designed for particular type of material to be mixed.
Size of agitator's clamping thread must be the same as the clamping thread in the mixer. It is forbidden to use downsizing ele-
ments to fi x the agitator in the tool. It is forbidden to remake mixer mounting or mounting of accessories to adjust them to each
other. To make sure that the agitator is properly fi xed, start the mixer without load for 30 seconds in safe position. In case of
excessive oscillations or other symptoms of improper operation or defect, immediately stop the device and check the correctness
of assembly. During trial start and during operation, a power cable should be kept away from the mixer. This will prevent the power
cable from being seized by the mixer which may lead to injuries and/or electric shock.
Provide patency of ventilation slots. If it is necessary, disconnect the product from power supply by removing the plug from mains
socket and clean the tool of dust. Do not use metal objects for this purpose.
Always wear protective googles and ear protectors. Other personal safety equipment such as anti-dust masks, gloves, helmets,
aprons should be worn. Long hair should be pinned up.
After switching off the tool , agitator is still rotating for a while.
Pay attention to prevent the agitator from hooking and/or seizing elements of clothes or hair. To this end, keep special care when
switching in and operating the tool.
O R I G I N A L
I N S T R U C T I O N S
12