P ONY F LOW 5 F U NCTI ONS R A P I D G U I D E
IGNITION: press any of the keys
Menu automatically.
EXTINCTION: this function can be set as parameter in the Setting Menu, or closing the door
of the display.
ZERO RESETTING OF PARTIAL VALUE: in Reading Menu, press the red button
few seconds, until the value is reset to zero.
SETTING MENU: you enter the Setting Menu to verify and eventually modify the following
parameters:
· PAGE 1: Language - Pulses per Liter - Unit Measure - Highlight.
· PAGE 2: Lighting time - Brightness - Extinction Time - Decimals.
Press the key
in the Reading Menu to enter page 1.
Use the keys
and
Use the key
to run through the messages.
Press the key
to move from page 1 to page 2.
Use the keys
and
Use the key
to run through the messages.
Press the key
to enter page 2 in the Reading Menu.
PROBLEM ENCOUNTERED
The instrument will not turn on
The instrument will not
indicate the ow rate
The instrument will indicate
a wrong ow rate
Will appear the battery symbol
,
to change parameters.
to change parameters.
P ROBLE MS , C AUS E S A ND C ORRE C TIV E
POSSIBLE CAUSE
The battery is completely exhausted
Power supply stopped
Defective owmeter sensor
Pony Flow is not perfectly screwed
onto the owmeter
Flowmeter impeller blocked
Impulses/liter value set is not correct
Flowmeter impeller slow
The battery is low
,
or
: for an instant; you enter the Reading
12
POSSIBLE CORRECTIVE
Replace the battery
Check cables and connector
between the battery and the
electronic card
Replace the sensor
Properly screw the instrument
onto the owmeter
Flowmeter maintenance
See chapter: "exact calculation of
impulses per liter"
Flowmeter maintenance
Replace the battery