P ONY F LOW 5 F U NCTI ONS R A P I D G U I D E
IGNITION: press any of the keys
Menu automatically.
EXTINCTION: this function can be set as parameter in the Setting Menu, or closing the door
of the display.
ZERO RESETTING OF PARTIAL VALUE: in Reading Menu, press the red button
few seconds, until the value is reset to zero.
SETTING MENU: you enter the Setting Menu to verify and eventually modify the following
parameters:
· PAGE 1: Language - Pulses per Liter - Unit Measure - Highlight.
· PAGE 2: Lighting time - Brightness - Extinction Time - Decimals.
Press the key
in the Reading Menu to enter page 1.
Use the keys
and
Use the key
to run through the messages.
Press the key
to move from page 1 to page 2.
Use the keys
and
Use the key
to run through the messages.
Press the key
to enter page 2 in the Reading Menu.
PROBLEM ENCOUNTERED
The instrument will not turn on
The instrument will not
indicate the ow rate
The instrument will indicate
a wrong ow rate
Will appear the battery symbol
,
to change parameters.
to change parameters.
P ROBLE MS , C AUS E S A ND C ORRE C TIV E
POSSIBLE CAUSE
The battery is completely exhausted
Power supply stopped
Defective owmeter sensor
Pony Flow is not perfectly screwed
onto the owmeter
Flowmeter impeller blocked
Impulses/liter value set is not correct
Flowmeter impeller slow
The battery is low
,
or
: for an instant; you enter the Reading
12
POSSIBLE CORRECTIVE
Replace the battery
Check cables and connector
between the battery and the
electronic card
Replace the sensor
Properly screw the instrument
onto the owmeter
Flowmeter maintenance
See chapter: "exact calculation of
impulses per liter"
Flowmeter maintenance
Replace the battery
for a