Operating temperature
When your air conditioner is used outside of the following temperature ranges, certain safety
protection features will activate and cause the unit to disable.
Inverter Split Type
Room Temperature
Outdoor
Temperature
Fixed-speed Type
COOL mode
Room
17°C-32°C (63°F-90°F)
Temperature
18°C-43°C (64°F-109°F)
-7°C-43°C (19°F-109°F)
Outdoor
(For models with low-temp cooling systems)
Temperature
18°C-52°C (64°F-126°F)
(For special tropical models)
NOTE: Room relative humidity less than 80%. If the air conditioner operates in excess of this
figure, the surface of the air conditioner may attract condensation. Please set the vertical air flow
louver to its maximum angle (vertically to the floor) and set HIGH fan mode.
To further optimize the performance of your unit, do the following:
Keep doors and windows closed.
Limit energy usage by using TIMER ON and TIMER OFF functions.
Do not block air inlets or outlets.
Regularly inspect and clean air filters.
www.coastair-ac.com
COOL mode
HEAT mode
17°C - 32°C
0°C - 30°C
(63°F - 90°F)
(32°F - 86°F)
0°C - 50°C
(32°F - 122°F)
-15°C - 50°C
-15°C - 30°C
(5°F - 122°F)
(5°F - 86°F)
(For models with
low temp. cooling
systems.)
0°C - 52°C
(32°F - 126°F)
(For special
tropical models)
DRY mode
10°C - 32°C
(50°F - 90°F)
0°C - 50°C
(32°F - 122°F)
0°C - 52°C
(32°F - 126°F)
(For special
tropical models)
HEAT mode
0°C-30°C
(32°F-86°F)
-7°C-24°C
(19°F-75°F)
8
IOM - DIY Heat Pump Series
FOR OUTDOOR UNITS
WITH AUXILIARY
ELECTRIC HEATER
When outside
temperature is below 0°C
(32°F), we strongly
recommend keeping the
unit plugged in at all
times to ensure smooth
ongoing performance.
DRY mode
10°C-32°C (50°F-90°F)
11°C-43°C (52°F-109°F)
18°C-43°C (64°F-109°F)
18°C-52°C (64°F-126°F)
(For special tropical models)