• Preheat on individual channels:
• Press "menu" and "up/down" until the display shows "Preheat".
• Press "menu" again: the display shows one of the 2 options.
• Press "up/down" until the display shows "Single"
• Press "menu" to select this option: the display shows the channel number on
the first row and the preheat level on the second row.
• Press "menu" to toggle between both rows.
• Press "up/down" to set the desired preheat levels and channel numbers until all
channels are set.
• Press "esc" to store the selected preheat levels and leave the menu.
• DMX ADDRESSING:
On the DSP12 you can set the DMX start address for the complete unit or for each
channel separately. Due to this "soft patch" option DMX addressing becomes
extremely flexible.
• Setting the start address for the complete unit:
• Press "menu" and "up/down" until the display shows "Dmx addr"
• Press "menu" again: the display shows one of the 2 options.
• Press "up/down" until the display shows "Block"
• Press "menu" to select this option.
• Press "up/down" to set the desired start address for the DSP12.
• Press "esc" to store the selected level and leave the menu.
• Setting the start address for individual channels:
• Press "menu" and "up/down" until the display shows "Dmx addr"
• Press "menu" again: the display shows one of the 2 options.
• Press "up/down" until the display shows "Single"
• Press "menu" to select this option: the display shows the channel number on
the first row and the DMX address on the second row.
• Press "menu" to toggle between both rows.
• Press "up/down" to set the desired DMX addresses and channel numbers until
all channels are set.
• Press "esc" to store the selected DMX addresses and leave the menu.
• PHASE CORRECTION:
To be able to produce perfectly linear curves the DSP12 has phase correction on
board. Normally this option should always be switched on. However some control
desks have built-in phase correction that can't be switched off. In these cases the
phase correction of the DSP12 can be switched off.
• Switching phase correction on/off:
• Press "menu" and "up/down" until the display shows "Pha corr"
• Press "menu" again: the display shows one of the 2 options (on/off)
• Press "up/down" until the display shows the desired option.
• Press "esc" to store the selected option and leave the menu.
JB SYSTEMS®
OPERATION MANUAL
9/60
DSP12
ENGLISH
SPECIFICATIONS
Power Input:
Single Phase 230Vac 50~60Hz (2 wires)
Three Phase 230Vac 50~60Hz (4 wires)
Power outputs:
Max. 12x 10A (max.10A per channel)
DMX-512 in/out:
in: male 3pin XLR
out: female 3pin XLR
Analog input:
SUB-D 15pin connector: 0~10Vdc
Size (WxHxD):
483 x 176 x 470mm
Weight:
25kg