HOMEPAGE
When you plug in the Tent-X for the first time, you will land on the
homepage on the LCD display. The homepage is where the climate
parameters of the tent and the nutrients and medium data are displayed:
02/06
09:30
800
1
PPFD
83.4
2
F
74.8
3
%
1200
4
PPM
02/06
09:30
1.36
10
mS/cm
73.0
7.94
11
F
3.17
14
mS/cm
57.4
15
F
The alarm symbol only appears when there's an alarm activated. The
internet symbol only appears when there's internet connectivity.
With the purchase and installation of the optional MBS-S8, you will have
the added benefit of tracking the CO2 levels in your grow tent.
04
Photosynthetic
6
5
1
Temperature
2
3
Humidity
Parts Per Million
4
Night mode
5
7
Day mode
6
8
Alarm activated
7
Internet
8
connected
Reservoir
9
9
Reservoir Electrical
10
Conductivity
Reservoir
11
temperature
Reservoir pH
12
level
Grow Medium
13
pH
12
Medium
14
Electrical Conductivity
13
Medium
15
65
temperature
%
16
Medium Water
16
Content
Additionally, with the purchase of the MBS-PAR sensor, you will also have
the ability to precisely track how much PPFD your plants are receiving.
Place the MBS-PAR sensor above the plant canopy and below the light
fixtures for the best results.
Climate control:
When you press ENTER on the Tent-X, you
Setting
Setting
will enter a setting page consisting of five
Temp
Day & Night
blocks, with each block serving a unique
2
2
Climate
function for climate control. The "Day&Night
Humid
Climate" tab is where you can set the climate
Light
Device
parameters for the grow tent. The "Light",
"Devices", and "EC Fans" tabs are where you
EC Fan
System
assign devices that can alter the climate in the
grow tent.
Day & Night Climate:
After pressing ENTER on the Day&Night
Day Setpoint
Climate tab, you will land on a page where you
Temp
Humid
CO2
can set the temperature, humidity, and CO2 in
the grow tent, for both day and night times.
70
65
1200
F
%
ppm
o
After the climate parameters have been set,
Night Setpoint
the climate devices will automatically maintain
Temp
Humid
CO2
the temperature, humidity, and CO2 levels.
You can also set alarms for your climate
55
400
50
o
F
ppm
%
parameters, in case the parameters are not
within the set range.
Light:
After pressing ENTER on the Light block, the
Lighting
Setting
screen will display Line 1 and Line 2. Use the
UP and DOWN arrows to choose Line 1 or
Line 1
Line 2 and press ENTER to navigate to the
page where you can make changes to the
selected Line.
Line 2
05