IR364
The connection to the anti-theft central must be done according to the following way:
PIR
M
NC
- +
FUNCTIONING
At the power of detector the LED flashes for approximately a minute; in this phase there is the stabilized
the sensibility of the pyroelectric sensor.
After the necessary time to the stabilization, the LED is off.
The intrusion detection activity opens the contact of exit NC and it is indicated from the ignition fixed of
LED; the contact NC is reinstated after about 3 seconds of the end of detection.
The sensitivity of the sensor can be regulated through the trimmer.
With the switch 1 of dip switch in ON it's possible to activate count impulsion function: at every
detection the LED emits a short flash but don't open the contacts NC and than remains inactive for 5
seconds.
After 6 detections the sensor signal the alarm with opening contacts NC and the ignition fixed of the
LED.
Passed 20 seconds from the last detection the counter pulse resets.
It's possible to eliminate reporting LED taking the lever switch 2 in ON.
ALARM MEMORY
The alarm memory function of the detector is useful when more detectors are installed on the same
zone; in such case, in fact, if the zone filler a memory alarm, with the traditional detectors is not possible to
know the detector that it has caused the alarm; with Ir364, instead, will be possible to identify it.
Is necessary to connect positive interrupted the coming one from it in such a way centers them antitheft
(+ Int.) on clip M.
In this way connecting the burglar alarm system the memory alarm function in the detector is activated, is
indicated from the flashing of about 3 seconds of LED; in this initial phase resets the eventual alarm memory
on the sensor.
If the sensor reports an alarm and to the central unit connected, the alarm memory is activated and the LED
flash everytime who reports the detection.
This LED functioning remains also when the central unit is after disconnected.
The normal fonctioning of LED in enabled to the following reconnection of the central unit.
4
PROG
DIP1
1 2
TAMPER
switch
sensibilità
In serie alla
linea 24h
Burglar central unit
in
in
Com
24H IMM
zone
security
-
+
+ int -
12Vcc
12V