Page 38
ENGLISH
If preventative measures are not taken, freezing water may cause severe damage to the cell and flow/temp/salinity
sensor. Prevent freeze damage to the cell and flow/temp/salinity sensor by running pump continuously or winterize
pool by draining water from pump, filter, and all intake and return lines. Remove the cell, clean and store it.
Disconnect the flow/temp/salinity sensor from the power center, then remove it from the vessel. Wrap flow/temp/
salinity sensor in a plastic bag or protective covering and coil flow/temp/salinity sensor and DC power cord cables
around the power center for storage.
An optional Spool Piece (sold separately) is available to replace the vessel during winterizing or vessel maintenance.
This will enable pool pump to circulate water with the vessel out the of line.
When a FREEZE CONTROLLER is used on pump equipment and the chlorinator is run through the winter, turn the
CHLORINE PRODUCTION down to 10 - 20%. Otherwise, chlorine production will exceed the recommended level
of 1.0 - 3.0 ppm.
NOTE A chlorine level above 3.0 ppm may cause corrosion of pool metals and possibly cause damage to associated
pool equipment.
Section 7.
Troubleshooting
NOTE Turn off power to unit prior to attempting service or repair.
7.1
Problems and Corrective Action
Problem
Low or no chlorine.
Zodiac
Nature
2
Fusion soft
®
®
Possible Cause
Low stabilizer (cyanuric acid) level in pool
water.
Insufficient operating hours of the unit
(outdoors pools only).
CHLORINE PRODUCTION percentage set
too low or off at 00%.
Recent increases in weather temperature
without increasing the chlorine production of
your unit.
Temporary loss of chlorine due to heavy
organic load - rain, leaves, fertilizer or heavy
bather load. Pets using pool.
Low (Less than 2.5) gpl salt level in pool
water.
High nitrate level.
Metals present in pool water.
New pool water. Not shocked properly upon
startup.
|
Installation and Operation Manual
Corrective Action
Add stabilizer to maintain 10 - 50 ppm.
Increase chlorine production by pressing
the Chlorine Production Rate Adjustment
button (arrow button B). See Section 5,
Operating Instructions.
Increase chlorine production by pressing
the Chlorine Production Rate Adjustment
button (arrow button B). See Section 5,
Operating Instructions.
Set "Boost" mode and allow to run for
24 hours. Recheck. If still too low, Super
Chlorinate with outside source. (Take
pool water sample to a qualified service
representative.) See Section 5, Operating
Instructions.
Test salinity by pressing the Test Salinity
button. See Section 4, Tables 2 and 3.
Contact a qualified service representative.
Contact a qualified service representative.
Super Chlorinate Pool. See Section 5.4,
Startup.