16
TROUBLE SHOOTING
BEFORE YOU START WORKING FOR THE ELIMINATION OF DEFECTS, DISCONNECT THE
MACHINE FROM THE POWER SUPPLY.
Fehler
Motor does not run
Loud noice when running
Drill runs erratically
Drill is hot and smokes
Motor runs but no rotation
or weak drilling power
MANY POTENTIAL SOURCES OF ERROR CAN BE CLEARED BY THE EXPERTLY
CONNECTION TO THE ELECTRICITY GRID.
Should you in necessary repairs not able to properly to perform or you
have not the prescribed training for it always attract a workshop to fix
the problem.
HOLZMANN MASCHINEN GmbH
Mögliche Ursache
Incorrect power supply
Switch defect
Motor defect
Safety switch activated
Incorrect belt tension
Drill chuck not assembled
correctly to arbour or one of them
is dirty
Drill chuck jaws worn or damaged
Spindle or boring is worn
Too fast speed for material being
drilled
Belt tension too low
Pulley belt diry, slippery
www.holzmann-maschinen.at
Let it be checked by a trained
person
Change
Change
Check the cover of motor pulley
(open?).
Adjust belt tension (1cm rule)
Check and adjust.
Change drill chucj
Check and replace if nesessary
Reduce speed
use lubricants
Tighten
Clean
N O T I C E
TROUBLE SHOOTING
Behebung
45
SB 4132SM