Specifications
Model Numbers:
TH6320ZW2003, TH6320ZW2007
Model Name: T6 Pro Z-Wave Thermostat
Model Description: Programmable Z-Wave
thermostat with touchscreen
Stages:
Up to 3 Heat / 2 Cool Heat Pump
Up to 2 Heat / 2 Cool Conventional
Power Requirements
Battery power: AA alkaline battery 3pcs.
C-wire input: 18-30VAC; 50Hz-60Hz
Electrical Ratings:
Terminal
Voltage
(50/60Hz)
W Heating
18-30 Vac
(Powerpile)
750 mV DC
W2 (Aux) Heating
18-30 Vac
E Emergency Heat 18-30 Vac
Y Compressor
18-30 Vac
Stage 1
Y2 Compressor
18-30 Vac
Stage 2
G Fan
18-30 Vac
O/B Changeover
18-30 Vac
L/A Input
18-30 Vac
Dimension: 4.09" x 4.09" x 1.06"
Display Size: 6.55 sq. in.
Temperature Ranges
Adjustable Heat Temperature Range Setting:
40-90 °F (4.5-32.0 °C)
Adjustable Cool Temperature Range Setting:
50-99 °F (10.0-37.0 °C)
Operating Ambient Temperature Range
Thermostat: 37-102°F (2.78-38.89 °C)
Operating Relative Humidity Range
Thermostat: 5% to 90% (non-condensing)
Temperature Sensor Accuracy
Thermostat: ± 1.5 °F at 70 °F (0.85 °C at 21.0 °C)
Physical Dimensions in Inches (mm) (H x W x D)
T6 PRO Z-Wave Thermostat
(TH6320ZW2003, TH6320ZW2007):
4-5/64 x 4-5/64 x 1-1/16 (104 x 104 x 27)
UWP Mounting System (included):
2-9/32 x 2-13/64 x 2-43/64 (58 x 56 x 10)
Z-Wave Radio:
Frequency (USA and Canada): 908.42 MHz
Certified: Z-Wave Plus V1 (TH6320ZW2003) V2
(TH6320ZW2007)
Generic Device Type: Thermostat
Node type (C-wire): Always On Slave (AOS)
Node type (Battery): Listening Sleeping Slave (LSS)
Z-Wave Chipset: ZM5202AU (TH6320ZW2003)
ZGM130S (TH6320ZW2007)
Supported Z-Wave Command Classes:
Indicator V3
Multi Channel Association V3
Firmware Update Meta Data V5
Z-Wave Plus Info V2
Supervision V1
Transport Service V2
Association V2
Version V3
Association Group Information V2
Basic V1 (TH6320ZW2003)
Basic V2 (TH6320ZW2007)
Battery V1
Clock V1
Configuration V4
Device Reset Local V1
Running
Manufacturer Specific V2
Current
Sensor Multilevel V5
0.02-1.0 A
Notification V3
100 mA DC
Powerlevel V1
0.02-1.0 A
Security 2 V1
Thermostat Fan Mode V3
0.02-0.5 A
Thermostat Fan State V1
0.02-1.0 A
Thermostat Mode V3
Thermostat Operating State V1
0.02-1.0 A
Thermostat Setpoint V2
0.02-0.5 A
NOTES:
0.02-0.5 A
Indicator V3: (TH6320ZW2007)
• The thermostat supports indicator (ID 0x50). To
0.02-0.5 A
trigger this feature, use your Z-Wave Gateway
identification function.
• When node identification is triggered by the
Controller, the thermostat screen will blink.
Basic V1 (TH6320ZW2003) V2 (TH6320ZW2007)
(basic set command implementation):
• Value 0x00 Device goes to Energy saving setting
(AWAY mode)
• Values 0x01-0x63 and 0xFF Device goes to
Comfort setting (HOME mode)
Notification V3:
• Notification V3 is enabled by default (Power
management alarm handling). Notification
Type: Power Management (0x08). Notification
Events: AC mains disconnected (0x02), AC mains
re-connected (0x03).
Security:
• All supported Z-Wave Command classes are
supported securely, except Transport Service V2,
Security 2 V1 and Z-Wave Plus Info V2
Association V2:
• Group ID: 1; Maximum Nodes: 1; Description:
Z-Wave Plus Lifeline.
• Group 1 notifies an associated device of a
change occurring in the thermostat. The changes
include status of the sensors, operating modes,
state of the thermostat, etc.
• Command Classes reported: Multilevel Sensor,
Thermostat Setpoint, Thermostat Mode,
Thermostat Fan Mode, Thermostat Operating
State, Thermostat Fan State, Battery, Device
Reset, and Notification.