Live wire alert
The device can detect AC cables at a 2" (51mm) depth when scanning in the stud or metal detection modes. When live AC voltage is detected,
the AC wiring alert icon (11) will appear on the screen.
AC scanning mode
Press the AC (AC mode) button to select the live wire detection mode. Complete the calibration and repeat the scanning procedure as described
above in the "Metal detection mode" section.
You can adjust the device sensitivity in this mode. Calibrating on the surface with previously detected AC cables reduces the sensitivity and
narrows the search area. After completing the calibration, repeat the scanning procedure as described above. You can reduce the sensitivity of
the device multiple times to narrow the search area even more and locate the live wire with greater accuracy.
Live wire detection will not work beyond a depth of 2" (51mm) from the scanned surface. Conduits encased in concrete, behind
sheer plywood, metallic wall coverings will cause very limited detection and may not be detected at all.
Low battery indicator
If the low battery indicator (3) starts flashing, immediately change the battery.
Specifications
Max. detection depth
Sound alert
Light alert
Operating temperature range
Power supply
Dimensions
Weight
The manufacturer reserves the right to make changes to the product range and specifications without prior notice.
Care and maintenance
Do not exclusively rely on the detector to locate items behind scanned surfaces. Do not assume that there is no live cabling inside a wall.
Always use caution when nailing, cutting, or drilling in walls, floors, and ceilings that may contain live cabling. Calibrate the device regularly.
Do not try to disassemble the device on your own for any reason. For repairs and cleaning of any kind, please contact your local specialized
service center. Protect the device from sudden impact and excessive mechanical force. Store the device in a dry cool place. Only use
accessories and spare parts for this device that comply with the technical specifications. Never attempt to operate a damaged device or a
device with damaged electrical parts! If a part of the device or battery is swallowed, seek medical attention immediately. Keep away from
children.
Battery safety instructions
Always purchase the correct size and grade of battery most suitable for the intended use. Always replace the whole set of batteries at one
time; taking care not to mix old and new ones, or batteries of different types. Clean the battery contacts and also those of the device prior
to battery installation. Make sure the batteries are installed correctly with regard to polarity (+ and –). Remove batteries from equipment
that is not to be used for an extended period of time. Remove used batteries promptly. Never short-circuit batteries as this may lead to high
temperatures, leakage, or explosion. Never heat batteries in order to revive them. Do not disassemble batteries. Remember to switch off
devices after use. Keep batteries out of the reach of children, to avoid risk of ingestion, suffocation, or poisoning. Utilize used batteries as
prescribed by your country's laws.
Levenhuk International Lifetime Warranty
All Levenhuk telescopes, microscopes, binoculars, and other optical products, except for their accessories, carry a lifetime warranty
against defects in materials and workmanship. A lifetime warranty is a guarantee on the lifetime of the product on the market. All Levenhuk
accessories are warranted to be free of defects in materials and workmanship for six months from the purchase date. The warranty entitles
you to the free repair or replacement of the Levenhuk product in any country where a Levenhuk office is located if all the warranty conditions
are met.
For further details, please visit: www.levenhuk.com/warranty
If warranty problems arise, or if you need assistance in using your product, contact the local Levenhuk branch.
live wire: 51mm (2")
non-ferrous metals: 60 mm (2½"), ferrous metals: 80 mm (3")
wood/metal studs: 13mm (½"), 25mm (1"), 38mm (1½")
+
+
0...+40°C (operating), −10...+50°C (storage) / +32...+104°F (operating),
+14...+122°F (storage)
2pcs AAA batteries
180x78x30mm (7.1x3.1x1.2in)
180g (0.4lb)