● OPERATING INSTRUCTIONS ●
S
ELECTING OPERATION MODES
1
Press
to start the operation.
2
Press
to select operation mode. Each press
changes mode in the following order:
(I FEEL )
(COOL)
3
Press
or
to set the temperature.
Each press raises or lowers the temperature by 1°F
(1°C).
Press
to stop the operation.
• The same setting is selected the next time by simply pressing
Operation indicator lamp
The operation indicator lamp shows the operation state of the unit.
Indication
Operation state
The unit is operating to reach the set
temperature
The room temperature is approaching the
set temperature
Lighted
Not lighted
En-5
(DRY)
(FAN)
.
Room temperature
About 4°F (2°C) or more
away from set tempera-
ture
About 2 to 4°F (1 to 2°C)
from set temperature
I FEEL mode
The unit selects the operation mode according to the room temperature when
I FEEL is selected. When the room temperature is higher than 77°F (25°C),
COOL is selected (set temperature: 75°F [24°C]). When the room temperature is
lower than 77°F (25°C), DRY is selected. However, when operation is stopped
and then started within 2 hours, the mode which has been selected previously
is operated.
Note:
During COOL operation, the set temperature may not be changed when the room
temperature is more than 4°F (2°C) higher than the set temperature. In this case,
please wait until the room temperature drops to within 4°F (2°C) of the set tem-
perature.
COOL mode
Enjoy cool air at your desired temperature.
Note:
Do not operate COOL mode at very low outside temperatures (less than 14°F
[-10°C]). Water condensed in the unit may drip and wet or damage furniture, etc.
DRY mode
Dehumidify your room. The room may be cooled slightly.
Temperature cannot be set during DRY mode.
FAN mode
Circulate the air in your room.
Emergency operation
When the remote controller cannot be used...
Emergency operation can be activated by pressing the emergency operation switch
(E.O.SW) on the indoor unit.
Each time the E.O.SW is pressed, the operation changes in the
following order:
Operation indicator lamp
Emergency COOL
Stop
Note:
The fi rst 30 minutes of operation is test run. Temperature control
does not work, and fan speed is set to High.
Auto restart function
If a power failure occurs or the main power is turned off during operation, "Auto restart
function" automatically starts operation in the same mode as the one set with the remote
controller just before the shutoff of the main power. When timer is set, timer setting is
cancelled and the unit starts operation when power is resumed.
If you do not want to use this function, please consult the service representative
because the setting of the unit needs to be changed.
Set temperature : 75°F (24°C)
Fan speed : Medium
Horizontal vane : Auto