SER/10MRE
11 Calza antenna
12 Centrale antenna. Si possono ottenere buone prestazioni, in termini di portata, collegando un filo di rame della lunghezza di 17 cm, ∅ 1 mm al morsetto 12
1. GENERAL INFORMATION
The SER/10MRE trigger box is conceived for commanding automatic roller blinds, electrically operated awnings and roller shutters and is equipped with an internal
memory capable of memorising up to 10 different codes generated by Multipass Roll series transmitters.
2. TECHNICAL FEATURES
Power supply
Average consumption
Reception frequency
Frequency stability
Sensitivity
Code
N° of codes memorisable
Relay contacts capacity
Signals
Working temperature
Storage temperature
3. FUNCTIONING METHOD
The functioning cycle is based on the sequence OPEN-STOP-CLOSE-STOP.
Activation commands may be given both through the terminal block and with Multipass Roll radio-control.
The command can be given with any Prastel Multipass and Multipass Roll series transmitter (433 Mhz). On the trigger boxes it is possible to buck the channel
address jumpers JP and set them as described below:
where "Channel 1" indicates the first channel of the transmitter, "Channel 2" the second channel of the transmitter etc..
The automation work time in the active phases (OPEN and CLOSE) can be varied by means of a trimmer, TR, from a minimum of 2 seconds to a maximum of
around 3 minutes.
There is a safety input on the terminal block, normally closed. This has the task of blocking the phase in course (OPEN or CLOSE) and then resuming, on reset of
the closure of contact, with the subsequent command.
4. PROGRAMMING AND CANCELLATION OF CODES
Operations of insertion into the memory of a new code or cancellation of the entire list of codes can be carried out on the receiver. Buttons P1 and P2.
PROGRAMMING
*
Hook-up the receiver correctly
*
Press button P1: the red led lights up to signal that the programming procedure is under way.
*
Press any transmitter button to carry out a transmission.
*
The code is inserted into the memory. During insertion the led lights up. On termination the led returns to the fixed light state to indicate that a new code may be
inserted.
*
Memorise all transmitters by carrying out a transmission with each of them.
*
At the end of the operation press button P1 again to exit the procedure. The LED switch off. In any case, exit from the programming procedure comes about
automatically 10 seconds after the last insertion of a code.
*
The codes remain memorised even if the receiver's power supply is cut off.
Warning: once the programming button has been pressed you have 10 seconds to carry out the first transmission.. If no transmission is carried out within this time
the receiver exits the programming phase automatically. To return to this phase you must press the programming button again.
TOTAL CANCELLATION OF CODES
*
Press button P2: the red led flashes.
*
Press button P2 again within 6 seconds to confirm cancellation. Confirmation is signalled by the led flashing at higher frequency.
5. TERMINAL BLOCK DIAGRAM
1 Incoming line 230Vac, neutral
2 Incoming line 230Vac, line
3 Motor (closure)
4 Motor (common)
5 Motor (opening)
6 - 24 Vdc (for auxiliary accessories)
7 + 24 Vdc 60mA (for auxiliary accessories)
8 STOP. When a contact NC between terminals 8-10 opens, the active phase under way is stopped. Resuming of movement takes place only on resetting the
PRASTEL s.r.l. Via del Vetraio, 7 40138 Bologna Italy - Tel. +39-51-533472 Fax +39-51-538460
SER10MRE 0
( UK ) JULY 1998
230 V ac
30 mA
433.92 MHz
± 180 ppm
Better than 1µV
Rolling
10
10A @ 230Vac
Red led
-15 / +55 °C
-40 / +85 °C
Channel 1
Channel 2
E-mail: info@prastel.com - Web site: http://www.prastel.com
Channel 3
Channel 4