Descargar Imprimir esta página

Remtron 325 OCU Guia De Inicio Rapido página 2

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Quick Start Guide
Remtron™ | 325, 411, 611 OCU and 10R, 17R MCU
1. Wire Your Machine Control Unit
The MCU terminals and pin numbering relative to the OCU buttons are identified in
the system configuration drawing provided with your system.
1.
In almost all cases the implementation of an appropriate main line contactor
power circuit is required using K18 and K19 to maintain the Machine power
and possibly K20 to reset the Machine, although this may be a local reset.
2.
Connect power and ground (per system specification) to J1 via a local
disconnect switch.
3.
Connect the correct antennas to the antenna connectors.
4.
Check the wiring and turn on the MCU power, the MCU LEDs, two power
green, Heartbeat flashing red and status amber will energize if all is OK , the
relays K18 and K19 will energize when the OCU is linked.
2. Install the Batteries
Rechargeable OCUs have tamper proof
screws on the battery cover. Disposable
battery (AA type) OCUs have cross head
screws on the battery cover.
4. Move to Active Mode
NB: For 2.4GHz Systems OCUs must have completed the Association process
with its target MCU (this only needs to be done once, see the user manual)
From Passive Mode the OCU can be moved into an Active mode;
1.
Press the Stop Switch and then press the On switch within 3 seconds.
2.
The Status E-Stop LED will now flash showing it is transmitting.
3.
At this point the OCU is active, and the target machine will be under direct
control.
4.
To shut the system down Press the Stop Switch.
5.
If the OCU is left in Passive mode, it will power down after 3 minutes.
Configuration Sheets and Manuals Are Available at Cattron.com
Nimble: 9M60-9061-A001-EN | May 2022
3. Turn On the OCU
1.
Press the ON button. The
OCU will wake from sleep to
a fully tested PASSIVE non-
transmitting mode.
2.
You will see all LEDs flash
briefly and the Haptic buzz to
confirm they are all working.
3.
The center status and right-
hand LEDs 1 and 2 will then
be illuminated.
ON
2nd
1st

Publicidad

loading

Este manual también es adecuado para:

411 ocu611 ocu10r mcu17r mcu