Technical data
Operating data
Operating pressure (ideal)
Operating pressure (max.)*
Operating pressure (min.)*
Water temperature (ideal)
Water temperature (max.)
Hole Size For Faucet
Certifies this faucet complies with ASME A112.18.1 / CSA B125.1, NSF/ANSI/CAN 61-2020
(AB100 compliant, Q<1 ) & NSF 372. The faucet also complies with water usage
requirements of the California Energy Commission and the US Department of Energy.
Installation instructions
1. Remove all contents from the package
and check for completeness.
2. Turn off water supply.
3. Cut a mounting hole 1 3/8" diameter
(35 mm) in the desired mounting
surface (if one isn't available).
4. Ensure Rubber O-Ring (2) is in place in
the Faucet Base (1) (fig. 2A).
2A
1
2
5. Insert the faucet into the hole, hoses
first (fig. 2B).
Attention: Rubber O-Ring (2) should
be sitting between the countertop and
faucet base.
Do not use putty or other sealant at this
location.
Notes: Solid surface installation: The
countertop mounting surface needs to
Value
60 PSI
4 bar
115 PSI
8 bar
30 PSI
2 bar
140°F
60°C
158°F
70°C
1 3/8"
35 mm
be flat and free of debris; otherwise the
faucet may not sit properly and could
leak.
6. Install the mounting hardware to the
mounting shank of the Faucet Base (1)
underneath the mounting surface in
the following order: Rubber Washer (3),
Plastic Flange (4) and Fixing Plate (5)
(fig. 2B).
2
2B
3
4
5
6
5
400 kPa
800 kPa
200 kPa
7 Nm