5.
MAIN Menu
Push K1 to enter into the Menu: the display shows the current value signaled by the blinking led
To modify select the value to modify scrolling the list with K1, then
Keeping K4 pressed, through K3 and K2 increase/decrease the value
To memorize wait for about 5 seconds or scroll the values through K1 button
MAIN Menu Parameters
Differential Thermostat
Buffer Max Thermostat
Integration Thermostat
6.
SECONDARY Menu
To enter into the Menu, press together K2 and K3 buttons for about 5 seconds
Press K3 or K2 to scroll the parameters codes: to visualize the value, press K4
To modify, keeping K4 pressed, through K3 and K2 increase/decrease the value
To memorize and return to the parameter display press K4 button
To exit and memorize, wait for about 5 seconds.
SECONDARY Menu Parameters
Collector Safety Thermostat
Buffer Safety Thermostat
Buffer Safety Thermostat
Collector Protection Thermostat
Safety Thermostat Hysteresis
Protection Thermostat Hysteresis
Differential Thermostat Hysteresis i12
Max Thermostat Hysteresis on T3 iT3max
Integration Thermostat Hysteresis iT3min
ANTIFREEZE Function Enable
ANTIFREEZE Thermostat
Time ON of P1:
ANTIFREEZE Function
Time OFF of P1: ANTIFREEZE Function
Time ON of P1:
TEST Function
Time ON of P1:
FILLING Function
7.
FAILURES or ALARMS Display
1.Lo:
T1< 0°C: Broken Probe
2.Lo:
T2< 0°C: Broken Probe
3.Lo:
T3< 0°C: Broken Probe
If the temperature read by any probe is higher than that of the Safety Thermostat
The display shows alternatively the temperature value and the message Sic
SILENCE Function: the acoustic signal can be turned off for 5 minutes by pushing any button.
T12
T3max
T3min
T1sic
T2sic
T3sic
T1Pro
iSic
iPro
T1ice
If the alarm condition persists, the acoustic signal restarts.
U.M.
Code
Min
°C
A31
03
°C
A26
20
°C
A25
05
U.M.
Code
Min
°C
A02
60
°C
A17
60
°C
A27
40
°C
A04
60
°C
i 10
1
°C
i 04
1
i 31
°C
1
°C
i 26
1
°C
i 25
1
- -
P06
0[off]
°C
A03
- 5
sec
t 05
5
min
t 06
1
sec
t 07
5
sec
t 08
5
1.Hi:
T1> 190°C: Probe in short circuit
2.Hi:
T2> 110°C: Probe in short circuit
2.Hi:
T3> 110°C: Probe in short circuit
Pag. 4 / 8
Default
Max
05
30
70
99
40
90
Default
Max
120
180
95
99
95
99
140
180
2
15
5
30
2
15
2
15
2
15
0 [off]
1 [on]
3
5
10
60
20
60
30
60
60
255
0CAR6IN016500
Set
Set