Maintenance
NOTE
• A newly installed filter may cause the water dispenser to spurt water briefly. This is
because air has entered the waterline.
• The replacement process may cause the water dispenser to drip for a short period of
time. If it drips, simply wipe up any water on the floor with a dry towel.
Reverse osmosis water filtration system
The water pressure of the water supply system to a reverse osmosis water filtration
system must be between 30 - 125 psi (206 - 862 kPa).
The water pressure of the reverse osmosis water filtration system to the refrigerator's
cold water line must be at least 30 psi (206 kPa). If the water pressure is below these
specifications:
• Check if the sediment filter in the reverse osmosis system is blocked. Replace the filter
if necessary.
• Refill the water tank in the reverse osmosis system with water.
• If your refrigerator has a water filter, it may further reduce the water pressure when
used in conjunction with a reverse osmosis system. Remove the water filter.
For more information or servicing, contact a licensed plumbing professional.
58
English
Untitled-2 58
1. Shut off the water supply line.
2. Turn the knob of the filter cartridge
90 degrees counterclockwise (1/4 turn).
The filter cartridge unlocks.
3. Pull out to remove the cartridge.
- If the water filter is severely
contaminated, the cartridge may not
be easy to remove. If that is the case,
use force to remove the cartridge.
- To prevent water leaks from the filter
opening, pull the cartridge straight
out while removing it.
4. Insert a new filter cartridge. Use only
Samsung-provided or approved filters.
5. Turn the cartridge knob clockwise to
lock into place.
6. Press and hold Ice Maker on the main
panel for 3 seconds to reset the life
cycle detector. The Filter Reset indicator
(
) turns off.
7. When you are done replacing the filter,
open the water valve and run water
through the dispenser for about 7
minutes. This is to remove impurities
and air from the water line.