LEAK TEST PROCEDURE
1. Attach hose assembly to the cylinder.
2. Slowly open the cylinder valve.
3. Perform a leak check on regulator to griddle hose to
regulator and hose to cylinder connections with soapy
water. Bubbles indicate a leak. Check that the connection
is not cross threaded and that it is tight.
4. Perform another leak check. Check the coupling nut for
tightness. If there is still a leak, remove the cylinder and
contact the manufacturer for service and repair.
5. When appliance is not in use, turn off the control knob
and LP tank valve on the supply cylinder.
6. Never use an LP tank if visibly rusted, damaged, or out of date.
7. If you notice grease or other hot material dripping from appliance onto the valve, hose or regulator, turn off gas supply at once.
Determine the cause, correct, clean and inspect valve, hose and regulator before continuing. Perform a leak test.
8. The regulator may make a humming or whistling noise during operation. This will not affect the safety or use of appliance.
9. Clean and inspect the hose before each use of the appliance. If there is evidence of abrasion, wear, cuts or leaks, the hose
must be replaced prior to the appliance being put into operation. See product tag for hose and regulator information.
10. Do not block holes in bottom or sides of appliance.
11. Never operate appliance with LP tanks out of correct position specified in Assembly Instructions.
12. Always close LP tank valve and remove coupling
nut before moving LP tank form specified operating
position.
13. NEVER store a spare LP tank under or near appliance or
in an enclosure.
14. If you see, smell, or hear escaping gas, immediately
get away from the LP tank/appliance and call your fire
department.
15. All spare LP tanks must have safety caps installed on the
LP tank outlet.
WARNING
Tripping hazard over hose and supply cylinder.
Make sure to attach the cylinder securely with the tank retention wire.
Do not operate the appliance on a tabletop higher than 39.8" (101.09 cm).
Make sure to the cylinder on a level surface and away from tripping
hazards.
Check for leaks at these connections.
Hose Length
23.35"(59.31cm)
Table Height
30" (76.2cm)