WARNING
Disconnect the electrical supply before performing maintenance to the vacuum cleaner.
Failure to do so could result in electric shock or personal injury from vacuum cleaner
suddenly starting.
Review this chart to find do-it-yourself solutions for minor performance problems. Any
service needed, other than those described in these Operating Instructions, should be
performed by an authorized service representative.
PROBLEM
Vacuum cleaner won't
start.
Poor job of dirt pick-up.
Vacuum cleaner starts
but cuts off.
Nozzle will not
run when attached.
Vacuum Cleaner picks up
moveable rugs -or-
Nozzle pushes too hard
Cord won't rewind.
BEFORE REQUESTING SERVICE
Electric Shock or Personal Injury Hazard.
POSSIBLE CAUSE
1. Unplugged at wall outlet.
2. Tripped circuit breaker/blown fuse
at household service panel.
3. Loose hose electrical connections.
1. Full or clogged dust bag.
2. Clogged airflow passages.
3. Dirty safety filter.
4. Open suction control.
5. Hole in hose.
6. Worn Multi-surface Nozzle brushes. 6. Replace agitator. (pages 46-48)
7. Worn or broken belt.
8. Dirty agitator or end caps.
9. Canister hood open.
1. Hose or hood electrical
connections.
2. Tripped thermal protector
1. Multi-surface Nozzle connections
unplugged.
2. Worn or broken belt.
3. Dirty agitator or end caps.
4. Switch not in carpet position
1. Suction too strong.
1. Dirty power cord.
2. Cord jammed.
POSSIBLE SOLUTION
1. Plug in firmly, push ON/OFF switch to
ON. (page 24)
2. Reset circuit breaker or replace fuse.
3. Reconnect hose ends. (page 18)
1. Change bag. (page 38)
2. Clear airflow passages. (page 50)
3. Clean filter. (page 40)
4. Adjust control. (page 36)
5. Replace hose.
7. Replace Nozzle.
8. Clean agitator and end caps. (page 46-
9. Close and latch hood.
1. Check connections, reconnect hose
ends. (page 18)
2. Reset thermal protector. (page 34)
1. Plug in firmly. (page 16)
2. Replace Nozzle.
3. Clean agitaor and end caps. (page 46-
4. Move switch to Carpet Position.
1. Open suction control. (page 38)
1. Clean the power cord.
2. Pull out cord and rewind. (page 22 & 24)