INSTALLATION ADVICE:
As the detector responds to changes in temperature, avoid the following situations:
Avoid pointing the detector towards objects with highly reflective surfaces, such as
mirrors etc. Avoid mounting the detector near heat sources, such as heating vents, air
conditioning units, light etc. Avoid pointing the detector towards objects that may move in
the wind, such as curtains, tall plants etc.
WARNING: Danger of death through electric shock! Must be installed by professional
electrician. Disconnect power source. Cover or shied any adjacent live components.
Ensure device cannot be switched on. Check power supply is disconnected.
CONNECTION:
Loosen the screw in the back and unload the bottom (refer to figure). Find the wire hole
with gasket in the downside of the sensor and pass the power wire through hole. Connect
the power wire into connection-wire column according to the connection-wire diagram.
Fix the bottom with inflated screw on the selected position (refer to figure ) Install back
the sensor on the bottom, tighten the screw and then test it.
CONNECTION-WIRE DIAGRAM: (See the right figure)
TEST: Turn the TIME knob anti-clockwise on the minimum (-).Turn the LUX knob anti-
clockwise on the maximum (sun).
– Switch on the power; the sensor and its connected lamp will have no signal at the
beginning. After Warm-up 30sec, the sensor can start work. If the sensor receives the
induction signal, the lamp will turn on. While there is no another induction signal any
more, the load should stop working within 10sec±3sec and the lamp would turn off.
– Turn LUX knob clockwise on the minimum (moon). If the ambient light is more than
3LUX, the sensor would not work and the lamp stop working too. If the ambient light is
less than 3LUX (darkness), the sensor would work. Under no induction signal condition,
the sensor should stop working within 10sec±3sec.
Note: when testing in daylight, please turn LUX knob to (SUN) position, otherwise the
sensor lamp could not work! If the lamp is more than 60W, the distance between lamp
and sensor should be 60cm at least.
SOME PROBLEM AND SOLVED WAY:
The load does not work:
a. Please check if the connection of power source and load is correct.
b. Please check if the load is good.
c. Please check if the settings of working light correspond to ambient light.
The sensitivity is poor:
a. Please check if there is any hindrance in front of the detector to affect it to receive
-2-
the signals.
b. Please check if the ambient temperature is too high.
c. Please check if the induction signal source is in the detection field.
d. Please check if the installation height corresponds to the height required
in the instruction.
e. Please check if the moving orientation is correct.
The sensor can not shut off the load automatically:
a. Please check if there is continual signal in the detection field.
b. Please check if the time delay is set to the maximum position
c. Please check if the power corresponds to the instruction.
PL
Czujnik ruchu na podczerwień z pilotem
Produkt wyróżnia się wysoką czułością poprzez zastosowanie układu scalonego.
Łączy w sobie automatyzm, wygodę użytkowania, bezpieczeństwo, oszczędność energii
oraz praktyczne funkcje. Urządzenie to wykorzystuje promieniowanie podczerwone
emitowane przez człowieka jako sygnał do rozpoczęcia pracy w momencie gdy ktoś
znajdzie się w zasięgu detekcji. Automatycznie wykrywa dzień oraz noc oraz jest łatwe
w instalacji i obsłudze.
SPECYFIKACJA:
Zasilanie: 220-240V/AC
Kąt wykrywania: 180°
Częstotliwość zasilania: 50/60Hz
Zasięg wykrywania: 12m max (<24°C)
Natężenie światła: <3-2000LUX (regul.)
Opóźnienie czasowe:
Min.10sec±3sec / Max.30min±3min
Uwaga: tryb krótkich sygnałów 1OS oznacza ze napięcie po 1 sekundzie uruchomi
urządzenie a po 9s wyłączy.
ZALETY: Urządzenie rozróżnia dzień i noc. Użytkownik może dostosować pracę
urządzenia w zależności od światła otoczenia. Urządzenie może pracować zarówno w
ciągu dnia jak i nocy gdy jest ustawione w pozycji „słońca" (max). Może także pracować
w otoczenia gdzie światło jest niższe niż 3 LX gdy urządzenie jest ustawione w pozycji
„księżyca". Jeśli chodzi o wzór regulacji, zapoznaj się ze schematem testowania.
Opóźnienie czasowe jest dodawane w sposób ciągły: po odebraniu drugiego sygnału
ruchowego, jeszcze w trakcie trwania pierwszego, urządzenie odlicza czas od momentu
zarejestrowania drugiego sygnału.
Temperatura pracy: -20/+40°C
Wilgotność pracy: <93%RH
Zużycie energii: ~0.5W
Max. obciążenie:
1200W 300W
Wysokość montażu: 1.8-2.5m
Szybkość wykrywanego ruchu: 0.6-1.5m/s
Zakres wykrywania: 50/75/100% (wybór)