Contents
1. Safety precautions ................................................................................................. 9
1.1. Before installation and electric work ..................................................... 9
1.2. Before getting installed ....................................................................... 10
1.3. Before getting installed (moved) - electrical work .............................. 10
1.4. Before starting the test run ................................................................. 10
2. Indoor unit accessories ....................................................................................... 10
3. Selecting an installation site ................................................................................ 10
3.1. Install the indoor unit on a ceiling strong enough to sustain its
weight ................................................................................................. 10
3.2. Securing installation and service space ..............................................11
3.3. Connecting indoor units to outdoor units .............................................11
4. Fixing hanging bolts .............................................................................................11
4.1. Fixing hanging bolts ............................................................................11
5. Installing the unit ..................................................................................................11
5.1. Hanging the unit body .........................................................................11
5.2. Confirming the unit's position and fixing hanging bolts .......................11
6. Connecting drain pipes ........................................................................................ 12
6.1. Drain pipe specifications .................................................................... 12
6.2. Drain pipe ........................................................................................... 12
6.3. Drain piping work ............................................................................... 12
6.4. Confirming drain discharge ................................................................ 12
Note: If you use other remote controllers, refer to either Installation Manual or Initial Setting Manual that comes with the controller to be used.
1. Safety precautions
1.1. Before installation and electric work
► Before installing the unit, make sure you read all the "Safety
precautions".
► The "Safety precautions" provide very important points
regarding safety. Make sure you follow them.
Symbols used in the text
Warning:
Describes precautions that should be observed to prevent danger of injury or
death to the user.
Caution:
Describes precautions that should be observed to prevent damage to the unit.
Symbols used in the illustrations
: Indicates an action that must be avoided.
: Indicates that important instructions must be followed.
: Indicates a part which must be grounded.
: Indicates that caution should be taken with rotating parts. (This symbol is
displayed on the main unit label.) <Color: yellow>
: Beware of electric shock (This symbol is displayed on the main unit label.)
<Color: yellow>
Warning:
Carefully read the labels affixed to the main unit.
Warning:
•
Ask the dealer or an authorized technician to install the air conditioner.
- Improper installation by the user may result in water leakage, electric shock, or
fire.
•
This appliance is not intended for use by persons (including children) with
reduced physical, sensory or mental capabilities, or lack of experience
and knowledge, unless they have been given supervision or instruction
concerning use of the appliance by a person responsible for their safety.
•
Install the air unit at a place that can withstand its weight.
- Inadequate strength may cause the unit to fall down, resulting in injuries.
Use the specified cables for wiring. Make the connections securely so that
•
the outside force of the cable is not applied to the terminals.
- Inadequate connection and fastening may generate heat and cause a fire.
•
Prepare for typhoons and other strong winds and earthquakes and install
the unit at the specified place.
- Improper installation may cause the unit to topple and result in injury.
Always use an air cleaner, humidifier, electric heater, and other accessories
•
specified by MITSUBISHI ELECTRIC CORPORATION.
- Ask an authorized technician to install the accessories. Improper installation by
the user may result in water leakage, electric shock, or fire.
7. Connecting water pipe ......................................................................................... 13
7.1. Important notes on water pipework installation .................................. 13
7.2. Water pipe insulation .......................................................................... 13
7.3. Water treatment and quality control ................................................... 14
8. Duct work ............................................................................................................ 15
9. Electrical wiring ................................................................................................... 16
9.1. Power supply wiring ........................................................................... 16
9.2. Connecting remote controller, indoor and outdoor transmission
cables ................................................................................................. 17
9.3. Connecting electrical connections ...................................................... 18
9.4. External I/O specifications .................................................................. 18
9.5. Selecting the external static pressure ................................................ 18
9.6. Setting addresses .............................................................................. 19
9.7. Sensing room temperature with the built-in sensor in a remote
controller ............................................................................................ 19
9.8. Changing the power voltage setting ................................................... 19
9.9. Electrical characteristics ..................................................................... 19
•
Never repair the unit. If the air conditioner must be repaired, consult the
dealer.
- If the unit is repaired improperly, water leakage, electric shock, or fire may
result.
•
If the supply cord is damaged, it must be replaced by the manufacturer, its
service agent or similarly qualified persons in order to avoid a hazard.
Do not touch the heat exchanger fins.
•
- Improper handling may result in injury.
•
When handling this product, always wear protective equipment.
EG: Gloves, full arm protection namely boiler suit, and safety glasses.
- Improper handling may result in injury.
•
Install the air conditioner according to this Installation Manual.
- If the unit is installed improperly, water leakage, electric shock, or fire may
result.
Have all electric work done by a licensed electrician according to "Electric
•
Facility Engineering Standard" and "Interior Wire Regulations" and the
instructions given in this manual and always use a special circuit.
- If the power source capacity is inadequate or electric work is performed
improperly, electric shock and fire may result.
•
Keep the electric parts away from water (washing water etc.).
- It might result in electric shock, catching fire or smoke.
•
Securely install the outdoor unit terminal cover (panel).
- If the terminal cover (panel) is not installed properly, dust or water may enter the
outdoor unit and fire or electric shock may result.
•
When moving and reinstalling the air conditioner, consult the dealer or an
authorized technician.
- If the air conditioner is installed improperly, water leakage, electric shock, or fire
may result.
•
Do not reconstruct or change the settings of the protection devices.
- If the pressure switch, thermal switch, or other protection device is shorted
and operated forcibly, or parts other than those specified by MITSUBISHI
ELECTRIC CORPORATION are used, fire or explosion may result.
•
To dispose of this product, consult your dealer.
•
Do not use a leak detection additive.
•
The installer and system specialist shall secure safety against leakage
according to local regulation or standards.
- The instructions in this manual may be applicable if local regulations are not
available.
•
Pay a special attention to the place, such as a basement, etc. where
refrigeration gas can stay, since refrigeration is heavier than the air.
•
Children should be supervised to ensure that they do not play with the
appliance.
•
This appliance is intended to be used by expert or trained users in shops, in
light industry and on farms, or for commercial use by lay persons.
9