Start-up
Preselect the speed of the abrasive belt according to
the speed table using the setting wheel.
Level
m/s
1
4.8
2
6.5
3
8.2
4
9.8
5
11.5
6
13.2
Never increase the belt speed adjusted
to the abrasive belt during operation!
Switching on/off
▸
Move the switch to the OFF position.
«0» is visible.
3
▸
To switch on the machine, press the switch and
slide it forward until it audibly engages.
«1» becomes visible.
3
▸
The lock is released by pressing the ON/OFF
switch.
The machine turns off.
3
Technical data
Art.
Nominal voltage
Power consumption
Power output
Band speed in No load
mode
Length of the abrasive belt
Width of the abrasive belt
Type of abrasive belt
Thickness of the abrasive belt
Sound pressure level
IEC 62841
Sound power level
rpm
3000
* The specified vibration emission values:
3400
4600
5800
7000
Operating conditions
8300
Machine protection
Starting current limitation
The electronically controlled soft start ensures a
smooth start of the machine. Due to the low starting
current of the machine, a 16 A fuse is sufficient.
Temperature-dependent overload
5706 110 X
protection
230/240V,
To protect against overheating, the safety electronics
50/60Hz
switch to cooling mode when a critical temperature
is reached. The machine then continues to run for
600 W
approx. 1300 min
are deactivated. After a cooling time of approx. 10
300 W
to 20 seconds, the machine is ready for operation
13.2 m/s
again.
▸
520 mm /
20 1/2"
3-19mm /
1/8"-3/4"
Low voltage protection / restart protection
Fleece and abra-
3
sive belts
max. 4 mm
▸
82 dB(A),
3
K=3 dB(A)
93 dB(A),
K=3 dB(A)
Art.
Vibration IEC 62841*
Weight without cable
Protection class
• Were measured using a standardised test method
and can be used to compare one electric tool
with another.
• Can be used for a rough assessment of the
exposure.
Operating temperature
range
Relative humidity
Operation
and the constant electronics
-1
Switch the machine off and on again to activate
the constant electronics. The temperature-depen-
dent overload protection reacts accordingly ear-
lier when the device is at operating temperature.
The machine stops if the supply voltage briefly
fails (disconnected plug, unstable supply network,
etc.).
After restoring the supply voltage, the machine
must be switched off and on.
The machine is ready for operation.
5706 110 X
2.5 m/s
,
2
K=1.5 m/s
2
2.2 kg
/II
0 to +50°C
95% at +10 °C
non-condensing
17