3.6
Restart interlock
The tool doesn't restart automatically when the power returns after an interruption in the supply. The on/off
switch must first be released and then pressed again to restart.
3.7
Items supplied
Breaker, side handle, operating instructions.
You can find other system products approved for your product at your local Hilti Center or online at:
www.hilti.com
4
Technical data
4.1
Breaker
For details of the rated voltage, frequency, current and input power, please refer to the power tool's
country-specific type identification plate.
When powered by a generator or transformer, the generator or transformer's power output must be at least
twice the rated input power shown on the rating plate of the power tool. The operating voltage of the
transformer or generator must always be within +5% and -15% of the rated voltage of the power tool.
Single impact energy in accordance with EPTA procedure 05/2009 11.5 J
Weight in accordance with EPTA procedure 01
4.2
Noise information and vibration values in accordance with EN 60745
The sound pressure and vibration values given in these instructions have been measured in accordance
with a standardized test and may be used to compare one electric tool with another. They may be used
for a preliminary assessment of exposure. The data given represents the main applications of the electric
tool. However, if the electric tool is used for different applications, with different accessory tools, or is poorly
maintained, the data may vary. This may significantly increase exposure over the total working period. An
accurate estimation of exposure should also take into account the times when the tool is switched off, or
when it is running but not actually being used for a job. This may significantly reduce exposure over the
total working period. Identify additional safety measures to protect the operator from the effects of noise
and/or vibration, for example: maintenance of the electric tool and the accessories, keeping the hands warm,
organization of work patterns.
Noise emission values
Sound (power) level (L
WA
Uncertainty for the sound power level (K
Emission sound pressure level (L
Uncertainty for the sound pressure level (K
Total vibration
Chiseling (a
)
h, Cheq
Uncertainty (K)
5
Operation
5.1
Preparations at the workplace
CAUTION
Risk of injury! Inadvertent starting of the product.
▶ Unplug the supply cord before making adjustments to the power tool or before changing accessories.
Observe the safety instructions and warnings in this documentation and on the product.
16
English
)
)
WA
)
pA
)
pA
7.9 kg
97 dB(A)
3 dB(A)
86 dB(A)
3 dB(A)
6.5 m/s²
1.5 m/s²
428075