AVENTICS | AV03/AV05/ES05, AES-Stand-Alone | R412019467–BAL–001–AD | English
English
1
About This Documentation
These instructions contain important information for the
safe and appropriate assembly of the product on a DIN rail
(R412019468).
O Read these instructions carefully, especially the
separate document "Notes on Safety" (R412015575),
before working with the product.
These instructions describe the assembly of the valve
systems AV03, AV05, ES05, and AES on a DIN rail.
Required and supplementary
documentation
O "Notes on Safety" (R412015575).
O Also follow the instructions for the other components
(e.g. bus coupler).
O Observe the system documentation from the system
manufacturer.
O Furthermore, observe all general, statutory and other
binding regulations.
Presentation of information
Warnings
In this document, there are safety instructions before the
steps whenever there is a danger of personal injury or
damage to the equipment. The measures described to
avoid these hazards must be followed.
Structure of warnings
Hazard type and source
Consequences of non-observance
O Measures to avoid these hazards
Meaning of the signal words
Indicates a hazardous situation which, if not avoided,
could result in minor or moderate injury.
Indicates that damage may be inflicted on the product
or the environment.
Symbols
Operation may be impaired if this information is
disregarded.
SIGNAL WORD
CAUTION
NOTICE
Abbreviations used
Abbreviation
Meaning
AES
Advanced Electronic System
AV
Advanced Valve
I/O module
Input/output module
ES
Essential Valve
2
Notes on Safety
O Observe all information contained in the separately
enclosed document Notes on Safety (R412015575).
Intended use
Only use the mounting kit for the DIN rail to mount the
AV03, AV05 and ES05 valve system and observe the
technical information in the main catalog.
3
Delivery Contents
W
1 set of assembly instructions
W
2x clamps
W
4x hexagon socket screws M4 x 8 DIN 912
W
1x hexagon socket screws M3 x 14 DIN 912
W
4x hexagon socket screws M4 x 16 DIN 912
4
Description and
Applications
The valve system can be mounted on a DIN rail
(DIN EN 50022, 35 x 15) and consists of the following
components:
W
End plate with D-Sub or IO-Link connector with hole for
mounting on the DIN rail or left end plate for bus
couplers and I/O modules:
W
Valve block with subbases, valves, supply plates or
blanking plates, according to ordered configuration
W
Bus couplers and I/O modules
W
Right end plate with hole for mounting on the DIN rail
Any mounting orientation may be used.
3