Activating the last cycle carried out
Check that the keypad is not locked and that
defrosting is not active.
1. Touch the SET key.
2. Touch the START/STOP key within 15 s.
Interrupting an operating cycle
Check that the keypad is not locked.
Touch the START/STOP key for 2 s.
Setting the cabinet setpoint during
conservation
Check that the keypad is not locked.
1. Touch the SET key.
2. Touch the UP or DOWN key within 15 s to set
the value.
3. Touch the SET key (or take no action for 15 s).
The setting is temporary. When a new cycle is
activated (and after a power failure), the device
will restore the r9/rA values.
Operating cycles
Initial information
Cycles managed:
Time controlled blast chilling and conservation
Time controlled blast freezing and conservation
Temperature controlled blast chilling and
conservation
Temperature controlled blast freezing and
conservation
Before each temperature controlled cycle, a
test is run to check that the needle probe is
correctly inserted.
The test consists of two phases. If the first
phase is completed successfully, the second
one will not be carried out.
If the test fails, the corresponding time
controlled cycle is activated.
CK640_ML_A5_v5_20221025.indb 19
CK640_ML_A5_v5_20221025.indb 19
Activating time controlled blast
chilling/freezing and conservation
Check that the keypad is not locked and that
defrosting is not active.
1. Touch the SET key to select a cycle.
Label
LED
Time controlled blast
PoS
chilling and conservation (if
E0 = 0 or 1)
Time controlled blast
nEG
freezing and conservation (if
E0 = 1 or 2)
2. Touch the DOWN key within 15 s to see the
duration of the blast chilling/freezing.
3. Touch the SET key.
4. Touch the UP or DOWN key within 15 s to set
the value.
5. Touch the SET key (or take no action for 15 s).
6. Touch the DOWN key within 15 s to see the
cabinet setpoint during blast chilling/freezing.
7. Touch the SET key.
8. Touch the UP or DOWN key within 15 s to set
the value.
9. Touch the SET key (or take no action for 15 s).
10. Touch the DOWN key within 15 s to see the
cabinet setpoint during conservation.
11. Touch the SET key.
12. Touch the UP or DOWN key within 15 s to set
the value.
13. Touch the SET key (or take no action for 15 s).
14. Touch the START/STOP key within 15 s.
The settings are temporary. When a new cycle is
activated (and after a power failure), the device
will restore the r1/r2, r7/r8 and r9/rA values.
Information about the active cycle:
Phase
Information displayed
Blast chilling/freezing
Residual time blast
active
chilling/freezing cycle
End (press a key)
End blast chilling/
freezing
Conservation active
Cabinet temperature
EN
Description
19