5.2 POWER PROTECT
The equipment must be operated by professionals; Make sure that the voltage of
power supply must be comply with the voltage identified on the lamp, and must have
an overload or leakage electrical protection.
ATTENTION!
Factory has equipped the standard 3 pin plug socket. Connect the power supply as
below table.
If lamp cable is damaged, replacement should be operate by factory or qualified
staff. Any question, please contact professionals or talk toa qualified electrician.
Live wire(L)
6. LAMP
6.1 LAMP DESCRIPTION
LAMP MODEL
OSRAM HRI 280
WARNING! There isa safety hazard or damage if install similar bulb
To reduce the risk of damage to light ,do change the lamp before using
time over 125% of lamp life.
6.2 LAMP REPLACE
Attention! When replace the lamp is forbidden to touch lamp with bare hand, to
avoid the greasy dirt stains filament. filament must be kept clean
1. Disconnect the power. Before replace lamp, fixture need 20 minutes for lamp
2. Use cross screwdriver to open the light body cover, remove the fan bracket,
3. Loose the screws for the fan take off the stand for the fan.
BEAM SPOT
Null(N)
RED
BLUE
POWER OF LAMP
280W
cooling. Fasten the head with Y axis protect lock in 60 ° position.
pull out the bulb cable
4.Press the lamp reflector slightly use one finger, and press the lamp bottom
slightly use another finger. So the lamp will loose from the stand.
5.Pull out the wires for the lamp
6.Install the Lamp
User Manual/Manual de uso
Ground wire
Yellow +Green
LIFE/HOUR
COLOR TEMPERATURE
2200 HOURS
Page 6
EN
8000K