Descargar Imprimir esta página

Farfisa CD2131PL Manual Del Usuario página 8

Ocultar thumbs Ver también para CD2131PL:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 12
EN
PROGRAMMING
Factory programming.
The values of the factory settings are
listed below. If you need to change
them, follow the instructions in the
following paragraphs.
- Door station address=231
- First button address=100
- Last button address (whole button
panel)=200
- Concierge address=empty
- Lock activation time=3 sec
- Operating mode EC/EM=activa-
tion on call and during conversa-
tion
- Line free tone=enabled
Programming via Bluetooth.
If it is necessary to change the fac-
tory configuration, it is suggested to
use the Bluetooth programming by
downloading the "DUO System" app
(available for iOS and Android) to
your smartphone or tablet. Then:
connect a Bluetooth programmer
PGR2991BT to the system;
launch the DUO System app, go
to the DUO Bus section, press the
"+" button, enter the door address
(factory setting 231);
program and disconnect.
In the event that a Bluetooth
programmer cannot be used,
an 'emergency' programming
procedure, described later, is
available but only a limited
number of parameters can be
programmed.
Enter into manual programming
mode.
Move jumper J1, located on the back
of the panel, from position 2-3 to 1-2;
the programming tone will be heard.
Jumper positions J1
1-2 = programming mode
2-3 = operation mode
Exit manual programming mode.
Set all dip-switches of MS1 and MS2
to OFF position and move jumper J1,
Mi 2380/2
- 8 -
located on the back of the control pa-
nel, from position 1-2 to 2-3.
Manual programming.
Once in programming, it is necessary:
set the code related to the function
by the dip-switches MS1 and MS2;
press the SW confirmation button;
use the dip-switches MS1 and MS2
to set the value of the selected fun-
ction;
press the SW confirmation button.
ON
1
2 3 4
ON
1
2 3 4
SW
MS1
MS2
Each time the SW button is pressed, a
confirmation or error tone will indica-
te whether a correct or incorrect code
has been entered; in the latter case,
the correct code must be re-entered.
Door station address program-
ming (code 177).
(Factory setting 231). Once in pro-
gramming:
by the dip-switches MS1 and MS2,
set the function code:
MS1
MS2
ON
ON
1
2 3 4
1
2 3 4
press the SW confirmation button;
by the dip-switches MS1 and MS2,
set the address (allowed values
231 to 250 - see Table 1); on the pi-
cture below the dip-switches MS1
and MS2 are configured for ad-
dress 231:
MS1
MS2
ON
ON
1
2 3 4
1
2 3 4
press the SW confirmation button.
If no further settings are required,
exit programming or continue with
the following paragraphs.
Programming the first button
address (code 161).
(Factory setting 100). Once in pro-
gramming:
by the dip-switches MS1 and MS2,
set the function code:
MS1
MS2
ON
ON
1
2 3 4
1
2 3 4
press the SW confirmation button;
by the dip-switches MS1 and MS2,
set the address (allowed values
001 to 200 - see Table 1); on the pi-
cture below the dip-switches MS1
and MS2 are configured for ad-
dress 100:
MS1
MS2
ON
ON
1
2 3 4
1
2 3 4
press the SW confirmation button.
If no further settings are required,
exit programming or continue with
the following paragraphs.
Programming the last button ad-
dress (code 162).
(Factory setting 200). Once in pro-
gramming:
by the dip-switches MS1 and MS2,
set the function code:
MS1
MS2
ON
ON
1
2 3 4
1
2 3 4
press the SW confirmation button;
by the dip-switches MS1 and MS2,
set the address (allowed values
from 001 to 200 - see Table 1. The
address of the last button must
be higher than that one of the first
button and refers to the whole ex-
ternal door station (including addi-
tional PL2..S); on the picture below
the dip-switches MS1 and MS2 are
configured for address 200:
MS1
MS2
ON
ON
1
2 3 4
1
2 3 4
press the SW confirmation button.
If no further settings are required,
exit programming or continue with
the following paragraphs.
Concierge address programming
(code 193).
(Factory empty). Once in program-
ming:
by the dip-switches MS1 and MS2,
set the function code:
MS1
MS2
ON
ON
1
2 3 4
1
2 3 4
press the SW confirmation button;
by the dip-switches MS1 and MS2,
set the address (allowed values:
201 if the call is sent to a main con-
cierge or 210 if it is sent to a se-
condary concierge. To delete the
previously saved value, enter 255

Publicidad

loading

Este manual también es adecuado para:

Cd2132plCd2134plCd2138pl