Descargar Imprimir esta página

MADER AGW-180E Manual página 53

Publicidad

Idiomas disponibles

Idiomas disponibles

S
D
P
HUT
OWN
1.
Release the trigger can stop the water flowing out. After did this, pls. engage the
trigger safety lock to avoid accidental "switch on".
In emergency condition: turn engine off immediately.
2.
Turn engine off. NOTE: NEVER turn the water off with the engine running.
3.
Turn water source off.
4.
Press trigger to release residual water.
5.
Disconnect all hoses used
6.
See storage section in this manual for proper storage procedures. Note: Let the engine
cool and up to 30 minutes after use before touching.
M
AINTENANCE AND
When doing maintenance, you may be exposed to hot surfaces, water pressure, moving parts,
or fire resulting in death. Before performing any maintenance or repair, disconnect power
source, let engine cool down completely and release all water pressure. The engine contains
flammable fuel. Do not smoke or work near open flames while performing maintenance.
N
OZZLE CLEANING
If the nozzle becomes clogged with foreign materials, such as dirt, excessive pressure may
develop. If the nozzle becomes partially clogged or restricted, the pump pressure will pulsate.
Clean the nozzle immediately using the nozzle kit supplied and the following instructions.
W
/L
AND
ANCE
1.
Shut off the pressure washer and turn off the water supply.
2.
Disconnect the wand/lance from the gun.
3.
Clean the nozzle using the nozzle cleaner provided or a straightened paper clip. Inset
into the nozzle end and work back and forth until obstruction is removed.
4.
Direct water supply into nozzle end to back flush loosened particles for 30 seconds.
5.
Reconnect wand/lance to gun and turn on water supply.
6.
Start pressure washer.
ROCEDURE
C
LEANING
50

Publicidad

loading