Preliminary conditions:
– Load limiter correctly mounted and wired.
– Adjustment screws unscrewed to the maximum.
– Hook free of any load.
Equipment required:
– A load (called "WLL") equivalent to 100% of the
nominal capacity authorized for the lifting machine.
– An additional load equivalent to 10% of the "WLL".
– A load "X" equivalent to the value of the "Wire rope
slack" threshold.
ACTIONS
The additional 10% represents
Lift the two loads
the overload value authorized in
1
(100% + 10% WLL)
accordance with the European
by about 10 cm.
directive.
Gradually screw in the threshold
adjustment screws (rep 3) until
the NC contact opens (§4.4).
Use a multimeter, for example,
Adjust the safety
2
to check the state of the contact.
threshold S1.
When the calibration is achieved,
lock the adjustment screw
by tightening the locking nut
(fig. 14).
Lift a load equal to the WLL by
Tightening the
10cm, repeat this operation 3
3
mounting screws
times then tighten the mounting
screws (fig.16) to 16 N.m +/- 2.
"It must be possible to lift the
«WLL» load. It must not be
possible to lift the «WLL» load
+ 10%. Depending on the lifting
speed, the dynamic effect
Check correct
4
may produce an unintentional
operation.
overload. In this case, consult
with a technician
capable of integrating a signal
filtering device (example:
timeout, etc.)."
Lift the intermediate
Wait for the load to stabilize
5
load "X".
before adjusting the threshold.
Gradually screw in the threshold
adjustment screws (rep 3) until
the NO contact opens (§4.4).
For more accuracy, take into
Adjust the
account the hysteresis in the
6
intermediate
setting. Use a multimeter, for
threshold S2.
example, to check the state of
the contact. When the calibration
is achieved, lock the adjustment
screw by tightening the locking
nut (fig. 14).
Check that the micro switch
Check correct
for threshold S2 trips when the
7
operation.
"Wire rope slack" condition is
reached.
6. Maintenance and periodic
verification
Tractel
recommends to periodically check correct
®
operation of the load limiter and the accuracy of the
threshold settings in accordance with the application
regulations.
No special maintenance is required for this type of
device. When performing periodic inspection, check
that the connecting cable to the control circuit is
properly secured and is in good condition.
IT IS FORBIDDEN TO:
– Use the load limiter without first becoming familiar
REMARKS
– Use the load limiter outside the validity periods
– Use the load limiter if its connection or condition are in
– Shunt the electrical circuit controlled by the device.
Copy of declaration conformity in appendix.
During storage and/or transport, the product must be:
– Packed in its original packaging
– Stored in a dry location
– Stored at a temperature between -30°C and 80°C
– Protected from chemical, mechanical or any other
10. Product disposal and environmental
The product must be disposed of in accordance with the
regulations applicable in the country of use.
The different product components must be recycled on
the basis of the table below, after separating metal and
synthetic materials. These materials must be recycled
by specialist organisations.
At the time of disposal, only trained individuals may
dismantle the product to separate its components.
Tractel
Tractel
7. Prohibited uses
with the user manual.
defined by the periodic inspection plan to which the
device is subject.
visibly poor condition.
8. Declaration of conformity
9. Transport and storage
type of attack.
protection
Component
Product body
Micro-switches
can recycle the product. Please contact
®
for more information.
®
To be treated as a
waste of the type
Aluminium & Steel
Electronics