Descargar Imprimir esta página

tibelec 579410 Manual De Instrucciones página 9

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 14
to a water supply or sink! Do not install the detector close to air conditioning or heating
systems. Choose your location carefully so that nothing can hinder detection and so that
the infrared sensor works properly. Avoid obstacles – the detection field must be free.
b. Connecting
For ceiling installation at over 170 cm (out of arm's reach) the detector is connected
between the original light switch and the light.
Drill the ceiling with a ø63mm hole saw.
It is powered by 4 wires – be sure to respect the colours :
230V = L : phase - brown - N : neutral - blue.
device to connect = L' : phase - brown - N : neutral - blue.
Connect the lamp to a Class II light fixture (not to be connected to earth).
• Shut off the power at your electrical board,
• remove your existing light fixture if necessary.
1
2
lampe
230V
lamp
230V
L
N
'
N
L'
L
DETECTOR
DETECTEUR
9

Publicidad

loading

Este manual también es adecuado para:

St45a