Track electrical connections
d Feed the grey negative charge connection
loom into the large hole at the rear of the
track section. Feed this wire through to the
end of the rail section. (Figure 18).
e Feed the power supply cable through the
same hole to the end of the rail section
(Figure 19).
f Place a cable tie around the power supply
cable (Figure 20).
g Pull the power supply cable tight at the
rear of the rail section. Using a cable tie,
attached the power supply cable to the
stanchion lug (Figure 21).
h Using two cable ties, securely fasten the
power supply cable to the back of the
stanchion as shown in (Figure 22)
i Connect the power supply cable and
negative charge connection loom to the
two-connector block (Figure 23).
j Wrap the two red charge contact wires
together and feed this into the two-way
connector block (Figure 24).
k Feed all of the wires into the end of the rail
section (Figure 25).
l Replace the stanchion bolt (Figure 26).
m Replace the end cap at the BOTTOM
OF THE STAIRS ONLY (Figure 26).
6 Fit the remaining bolts in to the top and
bottom track sections for the first and last
stanchion.
7 Fit the power supply to the wall using the
supplied bracket.
8 Terminate the power supply to the available
AC supply.
Note: All mains wiring must comply with the
local standards in force at the time of installation.
Do not fix the power supply to the stringer.