The application of mechanical force, for example, when
mounting the device on the casing may damage the glass body
of the reed switch.
Installation
Snap-on metal installation flange EF 8/20 on the contact and
magnet housing (see Figure 2).
Caution:
Measure the supply lines electrically before
connecting them!
Distance Diagram
See Figure 3.
Minimum switch-on distance: 9 mm,
tolerance in z: max. ±3 mm
Proximity/switch-on distance
Distance/switch-off clearance
Technical Data
Flush-mounted magnetic contact DC138R4.7 for EOL zone
types, tamper protected, with 2 integrated 4k7 resistors.
Note:
For front flush-mounted installation in ferromagnetic
materials.
Contact type
1 - pin NC contact
12 mm ±3 mm
Switching distance
Switching voltage
max. 100 V DC
Switching current
max. 500 mA
Contact rating
max. 6 W or 6 VA
max. 0.15 Ω
Contact resistance
Breakdown voltage
>250 V
Permissible operating
max. 40 V
voltage
Connection cable
LIYY 2 x 0.14 mm Cu tin-plated; suitable for
LSA IDC method of termination
External cable color
White
Internal conductor
Blue
Ø 8 x 32 mm with installation flange EF 8/20
Contact dimensions
(for 20 mm drilled diameter)
Ø 3.2 mm x 2 m
Cable dimensions
Ø 6 x 19 mm neodymium, axially polarized, in
Magnet
Ø 8 x 20 mm plastic sleeve with installation
flange EF 8/20 (20 mm drilled diameter)
Housing material
S-B or A-B-S, flange PA6 GF 30
Color
White
−25 to +70°C
Temperature range
Protection category
VdS - environmental class III, IP 67
Scope of Delivery
•
Ø
1 magnetic contact
2 / 10
Switch-on
Tolerance
distance [mm]
[mm]
±3
12
±2
13
8 x 32 mm with 1 flange EF 8/20
•
Ø
1 magnet
6 x 19 mm neodymium in plastic sleeve
Ø
8 x 20 mm with 1 flange EF 8/20
Regulatory information
Manufacturer
AUTHORIZED EU REPRESENTATIVE:
Carrier Fire & Security B.V.
Kelvinstraat 7, 6003 DH Weert, Netherlands
Product warnings
THESE PRODUCTS ARE INTENDED FOR
and disclaimers
SALE TO AND INSTALLATION BY QUALIFIED
PROFESSIONALS. CARRIER FIRE &
SECURITY CANNOT PROVIDE ANY
ASSURANCE THAT ANY PERSON OR ENTITY
BUYING ITS PRODUCTS, INCLUDING ANY
"AUTHORIZED DEALER" OR "AUTHORIZED
RESELLER", IS PROPERLY TRAINED OR
EXPERIENCED TO CORRECTLY INSTALL
FIRE AND SECURITY RELATED PRODUCTS.
For more information on warranty disclaimers and
product safety information, please check
https://firesecurityproducts.com/policy/product-
warning/ or scan the QR code.
Certification
EN 50131-2-6 Grade 3 by VdS
VdS no.
G110012 (Cl. C)
European Union
Carrier Fire & Security hereby declares that this
directives
device is in compliance with the applicable
requirements and provisions of the Directive
2014/30/EU and/or 2014/35/EU. For more
information see firesecurityproducts.com or
www.aritech.com.
REACH
Product may contain substances that are also
Candidate List substances in a concentration
above 0.1% w/w, per the most recently published
Candidate List found at ECHA Web site.
Safe use information can be found at
https://firesecurityproducts.com/en/content/intrusi
on-intro
2012/19/EU (WEEE directive): Products marked
with this symbol cannot be disposed of as
unsorted municipal waste in the European Union.
For proper recycling, return this product to your
local supplier upon the purchase of equivalent
new equipment, or dispose of it at designated
collection points. For more information see:
www.recyclethis.info
Contact information
firesecurityproducts.com or www.aritech.com
DE: Installationsanweisungen
Abbildungen
1
Magnetkontakt
2
Montage- und Anschaltplan
A
Kontakt
B
Magnet
3
Abstandsdiagramm
Näherungs-/Einschaltabstand
A
B
Entfernungs-/Abschaltabstand
C
Ruhebereich
P/N 31497300.Y71-ML • REV E • ISS 29NOV22