Αutomatic Modes - INVENTOR ΑΤΜ-25L Manual De Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 169
Lo
- Very Low Humidity
When the Room Humidity is ≤30%RH, this indication activates on the digital control panel of
the device.
• During this condition, the compressor stops and the fan keeps operating in the
selected settings.
• Once room humidity ≥32%RH detected, the compressor will resume its
operation in the previous settings.
Hi
- Very High Humidity
When the Room Humidity is ≥91%RH this indication steadily appears in the monitor of the
device.
• During this condition, the compressor will keep operating in the selected
settings.
• Once room humidity drops under ≤90%RH, the indication disappears.
8. ΑUTOMATIC MODES
AUTO-RESTART
The device memorizes the set operating conditions whenever power plug is connected. In the
event of a power failure the device performs Auto-Restart, once power is restored.
• In case of power failure or when the power plug unplugged from the socket,
the unit will operate in default settings prior to disconnection.
COMPRESSOR PROTECTION
The compressor continues to operate for five minutes once powered off for its protection.
EN
After Auto-Restart the setting of "Timer"
retained.
This attribute protects the compressor from unstable
functioning conditions, offering a longer life to the device.
cannot be
17