Slide the hoses over the nipples, pushing them right home and then fix them with appropriate tube nuts.
Before attaching the delivery hose to the plant, prime the peristaltic. Try to keep both the suction and discharge
hose as straight as possible, avoiding all unnecessary bends. Select the most appropriate injection point on a pipe
of the plant to be treated and there fit a 3/8" female steel gas thread connector (similar to BSPm). This connector
is not supplied with the pump. Screw the injection valve to the gas connector, inserting a gasket tape as Teflon.
Then connect the discharge hose to the conical connector on the injection valve and fix it with the supplied tube
nut. The injection valve also acts as no return valve by means of a cylinder sleeve
RACER COMPACT PH - RX
Features of e Pool
RACER COMPACT is a user-friendly equipment, made with a peristaltic pump and an electronic controller able to measure
and settle the chemical-physical values of a swimming pool, like the pH and the ORP (mV) values.
pH factory defaults: Setpoint= 7,2 pH; intervention: ACID
RX factory defaults: Setpoint= 700mV; intervention: OXIDANT
Controls
1)
2)
3)
Priming
Push SET + CAL key for, at least, 3 seconds to activate manually the peristaltic pump for the priming. releasing the buttons, the
pump stops
30
ENGLISH
30
SET key to select the Set-Point and confirm the setting Button to decrease the value
CAL key to activate the calibration and to increase the values Button to CAL/OK
Display LCD
Fig. 4
Command Display
.

Publicidad