Mark BEAM 195 Instrucciones De Usuario página 7

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

in the same method.
3. Using the safety cable which can withstand 10 times the weight of the equipment.
4. Make sure the X,Y protect locks are opened, Verify that within 3 meters there is no
combustibles .
WARNING
Fixture must use two fixing devices, and make sure the fixing device have locked! And only
fully clockwise rotate 90 ° can lock the hang fixture! Do remember plus a safety rope, and do
not connect the safety rope to plastic handle. It should be connect to the hole on the base!
4.3 FIXTURE CONNECT
Attention! One product only can accept one input one output.
BEAM 195
Pin 1, FOR GROUND; Pin 2 connected to the negative polarity signal; The pin 3
connected to the positive polarity signal.
DMX512 cable must use the professional shielded twisted pair cable; standard
loudspeaker cable is not reliable to control the long-range data.
Attention! Do not overload the connection. One continuous connection can only connect
up to 32 devices.
If use the DMX512 splitter. At first connect DMX512 Splitter input terminal to controller.
And then connected from the splitter output terminal to next device.
Do as above guide to connect other device, and finally coupled with terminal insertion
5. ALTERNATING CURRENT POWER SUPPLY
5.1 VOLTAGE, POWER, FUSE SPECIFICATION
Input Voltage
110~240V
Fuse voltage
250V
BEAM 195
DMX cable include 3 contact pins:
Total Power
250W
Electronic current Specification
6A
User Manual/Manual de uso
Frequency
50/60Hz
5×20