Operating instructions
SB 19 – 12/230V
Toggle switch up
 OFF
5
Maintenance and care:
The electric diaphragm pump is maintenance free.
Regularly check the pressure-carrying parts (pressure hose and nozzle) and the live parts of the
pump for possible damage or wear.. Replace defective parts immediately with original parts.
In order to avoid crystallization of the urea solution in the pump, the system must be completely
emptied and rinsed with a neutral liquid (water) when not in use for 2 weeks or longer.
Ordering spare parts:
When ordering spare parts, the following information is required:
Type specification, designation of the ET, order number
The following maintenance periods should be strictly observed to ensure trouble-free operation
Entire plant, visual inspection
Connection cable, terminal posts
Visual inspection
Pressure hose
Nozzle
Check for loose connections
Readability and availability of
information
6
Notes in case of malfunctions:
Symptoms
The engine does not run
Pump does not convey
Pump stops continuously
with the delivery.
MATO
/ Benzstr. 16-24 / 63165 Mühlheim a. Main / Tel:00 49(0)6108-906-0 / Fax: 00 49(0)6108-906-120
GmbH & Co. KG
Remove the nozzle from the
tank nozzle, lift it up and
actuate.
Before each use
X
X
X
X
Possible causes
Power plug not in socket
Terminal posts not connected
Battery is weak or empty
Wiring to the motor defective.
The container is empty
Suction filter is clogged
Suction filter is clogged
Let the liquid run back from
the hose into the container.
annually
X
X
X
Removal
Plug the mains plug into the socket
Connect terminal posts correctly
Check battery voltage.
Repair by qualified electrician
Check fill level in the tank.
Clean suction filter
Clean suction filter
Insert the nozzle in the
holder on the pump.
According to
manufacturer
X
11