Remote control operation
Three button mode remote control: OPEN/CLOSE/STOP of main engine are controlled by three buttons separately on the
remote control.
Single button mode remote control: OPEN/CLOSE/STOP of main engine are controlled by one button circularly on the
remote control.
OPEN
STOP
Three button mode remote control
Add extra remote control (remote control learning): Remove the main engine housing, then take out the upper cover of the
control box, press and hold the learning button REMOTES for 2 seconds, then the indicator light STS will be on; press the
button that to be learned on the remote control, the STS will be o ; remote control learning complete. A maximum of 25
remote controls can be learned.
Delete remote control: To delete remote control that have been learned; press and hold the learning button REMOTES until
the STS starts ash, all the matched remote controls will be deleted.
The fourth button on the remote control is for pedestrian mode, press the button while the door is closed, it will open for 1
meter which is for pedestrian only.
Note: To disengage gate opener, move the gate to the middle position, then close the clutch and press the open button of
external button switch to open the gate. If the gate opening direction is wrong, you can toggle switch MOT.DIRECTION or
exchange the motor phase-sequence lines MOT2 and MOT1. If the opening or closing limit is wrong, please exchange limit
switch lines which are connected to the corresponding terminal LSC and LSO on the control board.
Opening your life
Opening your life
CLOSE
PEDESTRIAN MODE
FIG 3
12
Bulldog
OPEN
CLOSE
STOP
Single button mode remote control
www.accessmatic.com
1522
BD1522
Code:
PEDESTRIAN MODE