Key
Description
A
Air hose
B
In-line Filter
C
Tee Fitting
To begin using the tool:
1.
As a standard practice, drain water from the
air compressor tank and air lines prior to use
each day (reference your compressor
operators manual for detailed instructions).
2.
Install a 1/4" NPT male connector into the air
inlet port on the tool (see Figure 2). Note:
Use Teflon® Tape on all threaded
connections.
3.
Turn on the air compressor and allow it to
build up pressure.
4.
Adjust the air compressor's regulator or the
supply line regulator to 90 PSI.
5.
Assemble the needle scaler attachment (Q)
to the end of the needle scaler body (S) (see
Figure 3). Tighten the 3 set screws (R)
located on the side of the needle scaler
attachment.
Keep hands away from
moving parts during operation.
6.
Connect the tool to the air hose quick
coupler. NOTE: It is recommended that
a whip hose with a swivel (not included)
be used to prevent twisting, kinking and
excessive wear to the air hose (ref. item
"F" in figure 1 for recommended
connections).
7.
Hold the needle scaler in an operating position against the work (with with needle scaler attachment properly
secured in place) before depressing the trigger. Gently squeeze the trigger and move slowly along the work
surface. Do not apply pressure to the scaler, let it do the work. Release trigger to stop tool.
Press needles against the against the work surface at a slight angle before depressing
the trigger. Remove needle scaler attachment from tool when not in use.
8.
When finished, turn off the air supply and hold the needle scaler a safe distance from yourself and others.
Squeeze the trigger to bleed off the remaining air. Disconnect the air hose.
TYPICAL INSTALLATION
Key
Description
D
In-line Oiler
E
Air Hose
F
Whip Hose
OPERATING INSTRUCTIONS
Key
Description
G Quick Coupler
H
Male Connector
I
Air Tool
L Exhaust port
M Trigger
N Teflon tape
O Air inlet port
P Male connector
Figure 3
4 - ENG
Figure 1
Key
Description
J
Female Connector
K
Spray Gun
Figure 2