3) Safety reverse force adjustment
4) Auto-close setting
5) Photo beam setting
6) O/S/C Terminal
Connecting a touch o switch to this terminal, you can use the switch when maintaining or the transmitter is left in garage(-
Figure 12).
Press „SET button and hold on until the LED displays "3". It´s under force adjust-
ment mode. Press "UP" button to increase the force and "DOWN" button to
decrease the force. The maximum force is 9 and the minimum is 1. Press "SET"
button to con rm.
Press "UP" button and hold on until the LED displays "_". Press "up" button once,
the auto-close time will increase 10 second, the maximum time is 9 minutes.
Press "down" button the auto-close time decrease 1 minute. The auto-close
function will be turned o when LED displays 0. Press "SET" button to con rm.
Press "DOWN" button and hold on until the LED displays "11", press "UP" button
the LED displays "H", photo beam function is available. Press "DOWN" button
the LED displays "11" to cancel this function. When setting is nished, press
"SET" to con rm. When connecting pulsed quantity control infrared sensor,
wiring as Figure 12. When infrared sensor is controlled by switch value, wiring
as Figure 13.
Notice: Close the photo beam function when you don't use photo beam
sensor.