9. Specifications
Specifications
Immersion depth
EN
Max. tensile force of the cable
Weight
Permissible temperature ranges
Switch-on time
Settling time
Wetted parts
Case
■
Sensor
■
Cable
■
Sealing
■
Protection cap
■
CE conformity
For further specifications see WIKA data sheet LM 40.04 and the order documentation.
22
max. 100 m [325 ft]
1,000 N
Submersible pressure sensor: approx. 300 g
Cable: approx. 80 g/m
Additional weight: 300 g
Medium: -10 ... + 50 °C [14 ... 122 °F] (Option: -40 ... +80 °C [-40 ... +176°F])
Ambient: -40 ... +80 °C [-40 ... +176°F]
Storage: -30 ... +80 °C [-22 ... +176°F]
Output signals without HART
®
Output signals with HART
: ≤ 250 ms
®
Output signals without HART
®
Output signals with HART
: ≤ 250 ms
®
316L (high-resistance option: 318LN)
316L (high-resistance option: Hastelloy C276)
PUR (high-resistance option: FEP)
FKM
PVDF
EMC directive, emission (group 1, class B) and interference immunity (industrial application)
WIKA operating instructions submersible pressure sensor, model LF-1
: ≤ 150 ms
: ≤ 100 ms