MAINTENANCE
WARNING
●
Before cleaning, stop unit operation with the remote controller and turn off the circuit breaker.
CAUTION
●
Do not expose the unit to water as it may cause an electric shock.
●
For cleaning inside the air conditioner, consult your sales agent.
●
Avoid using detergent when cleaning the heat exchanger of the indoor unit. Unit failure may result.
●
When cleaning the heat exchanger with a vacuum cleaner, make sure to wear gloves so as not to injure your
hands on the heat exchanger À ns.
1. AIR FILTER
Clean the air À lter, as it removes dust inside the room. Be sure to clean the À lter
once every two weeks so as not to consume electricity unnecessarily.
PROCEDURE
1
Loose the screw and release the À lter holders. Pull the À lter toward
center to take it out from indoor unit (refer to diagram).
2
Remove dust from the À lter using a vacuum cleaner. If there is too
much dust, use neutral detergent. After using neutral detergent, wash
with clean water and dry in the shade.
3
Install the À lters.
Slightly lift the suction grille and close as original state.
CAUTION
●
Do not wash with hot water at more than 40°C. The À lter may shrink.
●
When washing it, shake off moisture completely and dry it in the shade; do not expose it directly to the sun.
The À lter may shrink.
●
Do not operate the air conditioner with the À lter removed. Dust may enter the air conditioner and cause
trouble.
– 8 –
Filter
Filter
Indoor unit
Holders
Screws